Declaration of Incorporation 

 

We hereby declare that the following machinery is intended to be incorporated into other machinery, and must not be put into 

service until the relevant machinery into which it is to be incorporated has been declared in conformity with the essential 

requirements of the Machinery Directive, 2006/42/EC, and requirements of the Low Voltage Directive, 2006/95/EC. 

 

BS EN 61326-1: 2013 Electrical equipment for measurement, control and laboratory use – EMC requirements   

 

When using electrical equipment for control use, BS EN 61326-1 supercedes Electromagnetic Emissions  

EN 50081-2 and Electromagnetic Immunity EN 50082-2. 

 

Safety of Machinery:  

 

EN 60204-1: 2006 

 

Supplementary Information

:      

Machine Safety Report Number – 98021628.J02 

 

 

 

               Machine Safety testing performed by:  

Intertek Testing Services, 7435 4th Street North, Oakdale, MN 55128 

 

 

 

 

 

EMC testing was performed by Rodix at: 

 

 

 

 

L.F. Research, 12790 Route 76, Poplar Grove, IL 61065 

 

Machine Description: 

Vibratory Feeder Control 

 

Makes:

  CE-41 Plus, CE-41H Plus, CE-43 Plus, CE-43H Plus, CE-48, CE-48 Plus, CE-48H Plus, CE-49 Plus, CE-49H Plus, 

CE-91 Plus, CE-91H Plus, CE-91-2 Plus, CE-91-2H Plus, CE-91-3 Plus, CE-91-3H Plus, CE-93 Plus, CE-93H Plus, CE-98 Plus, 

CE-98H Plus, CE-98-2 Plus, CE-98-2H Plus, CE-98-3 Plus, CE-98-3H Plus, CE-99 Plus, CE-99H, CE-101 Plus, CE-101H Plus, 

CE-103 Plus, CE-103H Plus, CE-108 Plus, CE-108H Plus, CE-109 Plus, CE-109H Plus, CE-113 Plus, CE-113H Plus, CE-119 

Plus, CE-119H Plus, CE-201, CE-201-2, CE201-3, CE-201-4, CE-208 CE-208-2, CE-208-3, CE-208-4, SPE-606, and SPE-890. 

 

Types:

   

121-500-0606 

121-500-0700 through 121-500-0703 

121-500-0706 through 121-500-0721 

121-500-0724 through 121-500-0736 

121-500-0738 through 121-500-0795 

121-500-0890 

Manufactured by:  

Rodix, Inc. 

A technical construction file for this equipment is retained at the following address: 

2316 23rd Avenue, Rockford, Illinois 61104 

Date:  9/12/2014

   

 

 

 

                

Signature:

  

 

Title:  Vice President                                   

 

 

Name:  Jeff Johnson 

 

Summary of Contents for FEEDER CUBE CE-40 Plus Series

Page 1: ... Communication Systems LLC Figure 1 Warning label installed on the control Warning There is hazardous voltage inside the control Disconnect power before opening the enclosure Only skilled or instructed persons should open the enclosure An electrically instructed person is a person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid...

Page 2: ... SOFT Start trimpot clockwise for the gentlest start about a 6 sec ramp up to full output Turn the trimpot fully counter clockwise for no soft start 6 REMOTE OFF ON CONTROL A Run Jumper has been installed at the factory as shown on the enclosed wiring diagram Remote OFF ON operation of the FC 40 Plus Series Feeder Cube control can be configured to operate in one of the following ways A A low curre...

Page 3: ...ing or operating your Rodix Feeder Cube please call the factory or visit our web site Technical help is available to answer your questions and fax any needed information To return a control for IN or OUT of warranty service please ship it prepaid to Rodix Inc ATTN Repair Department If under warranty Rodix will repair or replace your control at no charge If out of warranty we will repair it and you...

Page 4: ... OUTPUT 10 INTERLOCK TERMINALS CE 90 PLUS SERIES FEEDER BOWL HOPPER INTERLOCK 11 9 6 CE 40 PLUS SERIES TERM STRIP TB 2 3 B 8 7 DC Voltage from PLC or CE 90 Plus C 12 10 9 LOW VOLTAGE INPUT SWITCHING INTERLOCK TERMINALS 8 CE 40 PLUS SERIES TERM STRIP TB 2 5 OFF ON CONTROL 11 10 30 VDC INPUT VOLTAGE 6 7 The common line is not fused in Europe The common line should be fused for North American machine...

Page 5: ...ons for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drain wire should be tied to the chassis in the Rodix control The drain wire should be kept shorter than 2 Please see the enclosed picture Example of a drain wire termination 2 Never run I O signal wires...

Page 6: ...sting was performed by Rodix at L F Research 12790 Route 76 Poplar Grove IL 61065 Machine Description Vibratory Feeder Control Makes CE 41 Plus CE 41H Plus CE 43 Plus CE 43H Plus CE 48 CE 48 Plus CE 48H Plus CE 49 Plus CE 49H Plus CE 91 Plus CE 91H Plus CE 91 2 Plus CE 91 2H Plus CE 91 3 Plus CE 91 3H Plus CE 93 Plus CE 93H Plus CE 98 Plus CE 98H Plus CE 98 2 Plus CE 98 2H Plus CE 98 3 Plus CE 98 ...

Page 7: ...the standard 1 When the standard does apply When a 230V machine is not powered by a step down transformer there should not be a problem meeting this standard if all the vibratory feeders on one machine operate in the 100 Pulse full wave mode and the combined total amperage for the vibratory feeders is 15 Amps or less However it is harder to meet this standard in the 50 Pulse half wave mode The com...

Page 8: ...p down transformer that is installed in a factory Thus the machine is powered by a higher voltage distribution system that is not directly connected to the 230V public low voltage system Because of this the machine is outside the scope of the standard1 A machine that is connected to 60Hz power is also outside the scope of the standard When the standard does apply The standard is applicable when a ...

Page 9: ...gether if they always start and stop at the same time Actual testing may prove that the number of On Off cycles shown in the chart can nearly be doubled when the Soft Start pot is adjusted for a one second or longer soft start Amps rms at 230V Maximum On Off cycles permitted 16 1 On Off cycle per 6 minutes 15 1 On Off cycle per 4 5 minutes 14 1 On Off cycle per 3 minutes 13 1 On Off cycle per 3 mi...

Reviews: