LINE VOLTAGE

LO A D

G

TERM. STRIP

(SMALL)

P/N 24-210

+

FC-40 PLUS

A C   HO T

A C   C O MMO N

AUX FEATURE

Pot Input

TB2

120

TB2

TERM. STRIP

4 -2 0 mA

(TALL)

+

TB1

-

-

TB1

S1

Direct

RUN

Interlock

H1

Mi

n

So

ft

60 Rev

Ma

x

TRANSFORMER

1

Sig.

-

SIG

100K

+ cw

C O NTRO L

1/8W MIN

MA IN

PO T

Gr/Yl #20 AWG

(Plug as disconnect)

Lt. 
B

u

 #

1

4

 A

W

G

B

l #1
4 A

W

G

3

B

l #1
4 A

W

G

12

4

4

Spare

6

7

10

Gr/Yl #14 AWG

SUB-PANEL

DOOR

Bl #14 AWG

12

Bl #14 AWG

12

F1

Lt. Bu #14 AWG

A1

B

l #1
4 A

W

G

12

Lt. Bu #14 AWG

Gate

A2

14

OUTPUT

B

l #1
4 A

W

G

3

3

V

i #2
0 A

W

G

Lt. 
B

u

 #

1

4

 A

W

G

4

4

3

GND

Gr/Yl #14 AWG

15 A

INTERLOCK
TERMINALS

7

9

RUN JUMPER

Bu #20 AWG

INT

E

R

L

O

C

K

RE
TU
R

N

DI
R

E

C

T

Bu #20 AWG

Bu #20 AWG

8

9

Lt. B

u

 #1
4 A

W

G

B

l #1
4 A

W

G

Lt. 
B

u

 #

1

4

 A

W

G

120 VAC

B

l #1

A

W

G

Gr
/Y

l #

1

4

AW

G

Bl

4

11

COM

Gn/Yl

50/60 Hz

1

20VK1

HOT

LINE FILTER

2

PE

Lt Bu

PE

Customer Supplied 
Disconnect Device

1

2

8

10

INTERLOCK

INPUT

11

6

8

8

12

60

External

SW3

SW5

-

+

SW4

5

2

11

5

See section 6 of the Application Note for more

details on the REMOTE OFF/ON CONTROL guide.

OFF/ON CONTROL GUIDE

P/N 123-293/123-294, 24-210/24/211

INTERLOCK

TERMINALS

6

LOW CURRENT

SWITCH

9

11

12

7

10

A)

8

CE-40 PLUS SERIES TERM STRIP TB-2

PADDLE

SWITCH

12

5

2

1

TERM STRIP TB-2, OUTPUT

10

INTERLOCK

TERMINALS

CE-90 PLUS SERIES

FEEDER BOWL/HOPPER INTERLOCK

11

9

6

CE-40 PLUS SERIES TERM STRIP TB-2

3

B)

8

7

(DC Voltage from PLC or CE-90 Plus)

C)

12

10 9

LOW VOLTAGE INPUT SWITCHING

INTERLOCK

TERMINALS

-

+

8

CE-40 PLUS SERIES TERM STRIP TB-2

5

OFF/ON CONTROL

11

10-30 VDC INPUT VOLTAGE

6

7

 

*** The common line is not fused in Europe.  The common line should be fused for North American machine installations.  Install the 
HOT & COM fuses external to the control, or install fuse(s) for each unit by cutting the common wire that goes from the switch to the 
terminal strip and add a fuse to it.  Then apply wire number labels to the wire that connects to the switch. 

Caution: Disconnect power before opening enclosure 
 
Installation instructions: 
When installing this control, a power supply disconnect device must be provided by the user.  A power plug/socket combination can 
be utilized for this purpose.  The plug and socket must have a breaking capacity of at least the amperage of the vibratory feeder(s). 
 
The size of the Mains supply wires should be 2.5mm² (#13 AWG) or larger. 
The Mains supply wires should be fused by the Customer at 15 amps or less. 

RODIX INCORPORATED 

2316 23

rd

 Avenue, ROCKFORD IL 61104 

TOLL FREE (800) 562-1868, FAX (815) 316-4701 

E-mail [email protected] 

www.rodix.com

 

 

CE-48 Plus W 24-211 

CE-41 

PLUS

 

P/N 121-500-0746 

10/17/12  

2000, 2012 RODIX INC

Summary of Contents for FEEDER CUBE CE-40 Plus Series

Page 1: ... Communication Systems LLC Figure 1 Warning label installed on the control Warning There is hazardous voltage inside the control Disconnect power before opening the enclosure Only skilled or instructed persons should open the enclosure An electrically instructed person is a person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid...

Page 2: ... SOFT Start trimpot clockwise for the gentlest start about a 6 sec ramp up to full output Turn the trimpot fully counter clockwise for no soft start 6 REMOTE OFF ON CONTROL A Run Jumper has been installed at the factory as shown on the enclosed wiring diagram Remote OFF ON operation of the FC 40 Plus Series Feeder Cube control can be configured to operate in one of the following ways A A low curre...

Page 3: ...ing or operating your Rodix Feeder Cube please call the factory or visit our web site Technical help is available to answer your questions and fax any needed information To return a control for IN or OUT of warranty service please ship it prepaid to Rodix Inc ATTN Repair Department If under warranty Rodix will repair or replace your control at no charge If out of warranty we will repair it and you...

Page 4: ... OUTPUT 10 INTERLOCK TERMINALS CE 90 PLUS SERIES FEEDER BOWL HOPPER INTERLOCK 11 9 6 CE 40 PLUS SERIES TERM STRIP TB 2 3 B 8 7 DC Voltage from PLC or CE 90 Plus C 12 10 9 LOW VOLTAGE INPUT SWITCHING INTERLOCK TERMINALS 8 CE 40 PLUS SERIES TERM STRIP TB 2 5 OFF ON CONTROL 11 10 30 VDC INPUT VOLTAGE 6 7 The common line is not fused in Europe The common line should be fused for North American machine...

Page 5: ...ons for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drain wire should be tied to the chassis in the Rodix control The drain wire should be kept shorter than 2 Please see the enclosed picture Example of a drain wire termination 2 Never run I O signal wires...

Page 6: ...sting was performed by Rodix at L F Research 12790 Route 76 Poplar Grove IL 61065 Machine Description Vibratory Feeder Control Makes CE 41 Plus CE 41H Plus CE 43 Plus CE 43H Plus CE 48 CE 48 Plus CE 48H Plus CE 49 Plus CE 49H Plus CE 91 Plus CE 91H Plus CE 91 2 Plus CE 91 2H Plus CE 91 3 Plus CE 91 3H Plus CE 93 Plus CE 93H Plus CE 98 Plus CE 98H Plus CE 98 2 Plus CE 98 2H Plus CE 98 3 Plus CE 98 ...

Page 7: ...the standard 1 When the standard does apply When a 230V machine is not powered by a step down transformer there should not be a problem meeting this standard if all the vibratory feeders on one machine operate in the 100 Pulse full wave mode and the combined total amperage for the vibratory feeders is 15 Amps or less However it is harder to meet this standard in the 50 Pulse half wave mode The com...

Page 8: ...p down transformer that is installed in a factory Thus the machine is powered by a higher voltage distribution system that is not directly connected to the 230V public low voltage system Because of this the machine is outside the scope of the standard1 A machine that is connected to 60Hz power is also outside the scope of the standard When the standard does apply The standard is applicable when a ...

Page 9: ...gether if they always start and stop at the same time Actual testing may prove that the number of On Off cycles shown in the chart can nearly be doubled when the Soft Start pot is adjusted for a one second or longer soft start Amps rms at 230V Maximum On Off cycles permitted 16 1 On Off cycle per 6 minutes 15 1 On Off cycle per 4 5 minutes 14 1 On Off cycle per 3 minutes 13 1 On Off cycle per 3 mi...

Reviews: