background image

CONNECT SINK OR SOURCE WIRE TO "SIG" INPUT

SENSOR OPTION

S

O -

BOWL/HOPPER

S

-

Bl #14

4-

20mA

-

Bl #14

1

E

4

+

Bu

LCD Display

TB3

13

9

5

INPUT POWER

85 - 264 VAC

SENSOR

+

Bl #

1

4

L2

Bl #14

TB1

14

F2

0-

10 V

D

C

BANNER

Bl #

1

4

Enable

JUMPER

SIG

Chassis

4

E

Load 

Out

S

+

Line 

Input

Aux Out

-

Bu

+

Bl #14

P1

R21

12

8

INTERLOCK OUTPUT

S

CFR Sensor

P/N 123-215

OUTPUT

TB4

Chassis

P/N 111-500

Analog

Bl #

1

4

Out -

LC D C ontrast

+

Br

Bl #

1

4

Out +

Danger!
Shock
Hazard

E

ACCEPTS BOTH OPTIC AND PROX SENSORS, NPN OR PNP.

+

An

al

o

g

 Gn

d

.

11

7

MASTER CONTROL

SM312FP1H

OPTICS

INPUT

3

Bl

OPTIC SENSOR

1

-

RUN

2

R27

High Voltage LED

L1

O +

Tighten Main Terminals 

to 9 in. lbs.

+

Accel.

L1

TB2

1

F1

-

Br

Gr

/Y

l #

1

4

Keypad

2

-

+

1

L2

10

6

3

3

1

TB2

-

12VDC, <1 WATT

1N4006 DIODE

-

SIG

AIR VALVE

Air-Valve Connections

           Figure 2

+

+

Aux Out

2

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

      

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 

RODIX, INC.

 

Toll Free (800) 562-1868, FAX (815) 316-4701

 

Email [email protected] 

rodix.com 

 

 

VF-3-OR cover.docx 6/2/2017  Page 2 

 

RODIX INC. 

FEEDER CUBE

 

VF Series 
WIRING DIAGRAM 

 

 

Figure 1 

Summary of Contents for Autotune Series

Page 1: ...Rated Output Current 3 Amps at 120V or 1 5 Amps at 240V Rated for IP54 environment UL rated for Type 5 environment Model Information The Autotune Series of Variable Frequency Feeder Cubes generates an...

Page 2: ...Bl 14 Out LCD Contrast Br Bl 14 Out Danger Shock Hazard E ACCEPTS BOTH OPTIC AND PROX SENSORS NPN OR PNP Analog Gnd 11 7 MASTER CONTROL SM312FP1H OPTICS INPUT 3 Bl OPTIC SENSOR 1 RUN 2 R27 High Voltag...

Page 3: ...nnecting TB1 L2 to the L2 fuse holder Remove the terminal end of the wire connecting the L2 fuse to the power switch and connect it to TB1 L2 1 Parts Sensor Input Photo sensor or Proximity Switch Conn...

Page 4: ...or below the minimum power setting level The amplitude power setting is displayed in the following manner A 50 0 8 Limiting The Maximum Output Of Control The Max Amplitude setting can be adjusted to...

Page 5: ...g is enabled the normal display menu will show a bold F When is shown in bold the control is locked onto the resonate frequency of the feeder C The frequency can be adjusted with an analog 0 10 volt i...

Page 6: ...n will put the original factory settings into the memory 23 Language The run display and programming menus can be set to display in English Spanish Espa ol French Fran ais or German Deutsch 24 Over Cu...

Page 7: ...nate control Steps to Interlock an FC 40 Plus Series to a VF Series Control 1 Add a wire from terminal 2 of the VF master control to TB2 11 of the subordinate control 2 Add a wire from terminal 3 of t...

Page 8: ...r Resets Control to Factory Default Settings Shown in bold Language Pick Language English Espa ol Spanish Fran ais French Deutsch German Normal Display Message Priority The normal operating display sh...

Page 9: ...ensor at least 20 minutes to cure before operation Note It takes 72 hours for the adhesive to fully cure at 70 F Alternatively 8 or M4 screws can be used to mount the sensor to the feeder The mounting...

Page 10: ...f a nearby noise source Solutions for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock inpu...

Reviews: