E1001A-171107
21
11- Tightly put electrical tape at each end of the sheath in order to squeezing the
rubber and metallic strips.
12- Put MOLYKOTE 33 LIGHT grease (Extreme low temperature grease) on the
probe’s threads, on the electrical tape, on the inner wall of yellow vulcolan rings,
and on the flat inner side of the brass knurled nut.
13- Push by hand the yellow ring in place over the probe. Put the brass knurled nut in
place and screw it. This will push the yellow ring inward. Proceed until three
threads can be seen.
14- Free the probe from the vice and from the vice adaptor, then reinstall it on the
vice but on its other end.
15- Make sure that the metallic strips are still straight. Put the yellow ring and knurled
nut on this end of the probe.
16- Using a strap wrench, keep on tightening the knurled nut until 5 to 6 threads can
be seen.
17- Free the probe from the vice and reinstall it on its other end. Tighten the knurled
nut until 5 to 6 threads can be seen.
18- Installation completed.