![ROCTEST FOS Series Manual Download Page 5](http://html1.mh-extra.com/html/roctest/fos-series/fos-series_manual_1476395005.webp)
E10190-000816
FOS
Page 3
1.3 SPECIFICATIONS
Gauge type:
FOS:
Standard fiber-optic strain gauge
FOS-N:
Non temperature compensated FOS
FOS-C:
Temperature compensated FOS
FOS-B:
FOS encapsulated in a blade
FOS-R:
FOS encapsulated in a rod
Stain range (microstrains):
±1 000, ±2 000, ±3 000, ±5 000
0 to 2 000, 0 to 3 000, 0 to 5 000
minus 2 000 to 0, minus 3 000 to 0, minus 5 000 to 0,
(other available on request)
Resolution:
0.01% of full scale
Precision:
Range dependent
Transverse sensitivity:
0.1% of full scale
Response time:
Readout unit/data logger dependent
Operating temperature:
Minus 55°C to +350°C; operating temperature is fiber-
optic cable dependent
EMI/RFI susceptibility:
Intrinsic immunity
Combatibility::
All ROCTEST's fiber-optic readout units and data loggers
Cable length:
1.5 meter length. Custom length up to 5 km available
Gauge dimensions:
310 microns diameter
Fiber-Optic Cable:
4.0 mm O.D. polyurethane jacket Kevlar
reinforced
(minus 55°C to +85°C), or 1 mm O.D. braided fiberglass
cable (minus 55°C to +350°C)
Gauge material:
Glass
Connector:
ST Connector