![Rockwood 31837 Instructions Manual Download Page 7](http://html1.mh-extra.com/html/rockwood/31837/31837_instructions-manual_1475928007.webp)
To order parts and supplies: 800.343.9353 >> eastwood.com
7
Tool doesn’t
respond to
Throttle
rotation
Insufficient
volume of air
(CFM) to oper-
ate tool
Verify sufficient air supply to tool.
(4 CFM @ 90 PSI minimum requirement).
Moisture or
other contami-
nation in air
supply
Check for moisture in air line and tool air inlet.
Tool perfor-
mance is slow
or sluggish
Insufficient
volume of air
(CFM) to oper-
ate tool
Verify sufficient air supply to tool.
(4 CFM @ 90 PSI minimum requirement).
Moisture or
other contami-
nation in air
supply
Check for moisture in air line and tool air inlet.
Air Motor is
lacking lubrica-
tion
Stop use immediately and add air tool oil
directly to air inlet.
Tool is exces-
sively noisy/
emits high
pitched sound
Air Motor is
lacking lubrica-
tion
Stop use immediately and add air tool oil
directly to air inlet.
Tool vibrates
excessively
during use
Out of balance
condition from
damaged ac-
cessory
Stop use immediately, check for damage and
replace accessory.
Loose Collet
Retainer
Tighten loose Collet Retainer securely.
TROUBLESHOOTING