Publication SAFETY-AT017B-EN-P-July 2011 

Reproduction of the contents of this manual, in whole or in part, without 
written permission of Rockwell Automation, Inc., is prohibited. 

Throughout this manual, when necessary, we use notes to make you 
aware of safety considerations. 

 

Identifies information about practices or circumstances that 

can cause an explosion in a hazardous environment, 

which may lead to personal injury or death, property 

damage, or economic loss.

 

 

Identifies information that is critical for successful 

application and understanding of the product.

 

 

Identifies information about practices or circumstances that 

can lead to personal injury or death, property damage, or 

economic loss. Attentions help you identify a hazard, avoid 
a hazard, and recognize the consequence.

 

 

Labels may be on or inside the equipment, for example, a 

drive or motor, to alert people that dangerous voltage may 
be present.

 

 

Labels may be on or inside the equipment, for example, a 

drive or motor, to alert people that surfaces may reach 

dangerous temperatures.

 

General Safety Information 

 

This application example is for advanced users and 
assumes that you are trained and experienced in safety 

system requirements.

 

 

A risk assessment should be performed to make sure all 

task and hazard combinations have been identified and 

addressed. The risk assessment may require additional 

circuitry to reduce the risk to a tolerable level. Safety 
circuits must take into consideration safety distance 

calculations which are not part of the scope of this 

document.

 

Contact Rockwell Automation to find out more about our safety risk 
assessment services. 

Summary of Contents for GuardLogix

Page 1: ...Safety Controller Safety Rating Category 3 also see Achieving a Cat 4 Safety Rating according to EN954 1 Introduction 2 Important User Information 2 General Safety Information 3 Description 4 Setup a...

Page 2: ...owerFlex DriveGuard drives to replace external power contactors A drive with safe off capabilities can offer increased productivity through reduced downtime Important User Information Solid state equi...

Page 3: ...p you identify a hazard avoid a hazard and recognize the consequence Labels may be on or inside the equipment for example a drive or motor to alert people that dangerous voltage may be present Labels...

Page 4: ...ithin programming logic are satisfied the safety outputs of the EtherNet IP Guard I O safety module can be enabled These safety outputs are used to control the Safe Off and Drive Enable inputs on the...

Page 5: ...ling and wiring refer to the product manuals listed in the Additional Resources System Overview Wiring This diagram shows the appropriate wiring EtherNet IP Guard I O GuardLogix Controller PowerFlex 7...

Page 6: ...d for Drive Enable This input must be controlled by the Guard I O Safety module The Drive Enable digital input on the PowerFlex 70 drive is a solid state circuit For this reason the safety outputs on...

Page 7: ...Fault Immediate Reaction Immediate Detection P HI Short HI Undetectable M HI HI P HI LO M HI Short LO Yes Short to 0V Channel Start Fault Immediate Reaction Immediate Detection P HI Short LO Yes M HI...

Page 8: ...g methods Adjust the three switches on the front of the module Use a Dynamic Host Configuration Protocol DHCP server such as Rockwell Automation BootP DHCP Server Utility Retrieve the IP address from...

Page 9: ...by the MAC address listed on the EtherNet IP Guard I O safety module The MAC address is displayed in the BootP DHCP Server Utility as shown 2 Select the entry with the MAC address that corresponds wit...

Page 10: ...1791ES IB8XOBV4 module is added to the I O Configuration under the 1756 ENBT EtherNet IP bridge module as shown Set the Module Properties The 1791ES IB8XOBV4 module is configured as follows 1 On the...

Page 11: ...ngle status bit The same is true for Output Data For status bits for individual input output test points choose an alternative Input Output Status data format 4 Make edits on the Connection and Safety...

Page 12: ...e are configured as Safety Pulse Test and utilize Test Sources 0 and 1 respectively 4 Select Inputs 2 and 3 for the Interlock Switch These are configured as Safety Pulse Test and utilize Test Sources...

Page 13: ...tion Rockwell Automation recommends that the safety outputs are configured as Safety Programming This section details how to program your GuardLogix project based on the wiring and configuration detai...

Page 14: ...E stop instruction provides SIL 3 level diagnostics for a dual channel emergency stop function The E stop monitors input channels for consistency and detects and traps faults inconsistency greater tha...

Page 15: ...m restarting if the E stops reset automatically The InputOK status is used as one of the permissives in the safety output routines Gate Switch Safety Logic The RIN instruction provides SIL 3 level dia...

Page 16: ...ed to reset or enable the safety zone output The operator action is a HI transition of Cmd_Zone1_SafetyReset It latches the output enable until either a demand is placed on a safety input there is an...

Page 17: ...to the PowerFlex 70 Safe Off relay and Drive Enable digital input Reassignment of the feedback and output channels must be made to match your unique safety wiring configuration Performance Data Worst...

Page 18: ...B Input Connection Reaction Time Limit CTRL The Connection Reaction Time Limit is configured in the 1791ES Module Properties within RSLogix 5000 software The Input Connection defaults to 4 x RPI C Gu...

Page 19: ...on Reaction Time Input RPI C GuardLogix Delay The typical delay time for the GuardLogix controller is Period 2 Task Scan Time D Output Connection Reaction Time Output RPI Task Period E Output Module D...

Page 20: ...tin 100S Safety Contactor 1 Choose a safety contactor that is rated for your application requirements Modified Wiring Schematic This wiring diagram using a safety contactor illustrates turning off pow...

Page 21: ...onfiguration The safety Output Configuration for the Guard I O module can now be configured for Safety Pulse Test With Safety Pulse Test configured shorts of the P terminal to 24V and shorts of the M...

Page 22: ...y Application Instruction Set for the GuardLogix Controller GuardLogix Controller Systems Publication 1756 RM03 Explains how the GuardLogix controller can be used in safety applications DriveGuard Saf...

Page 23: ...23 Publication SAFETY AT017B EN P July 2011 Notes...

Page 24: ...l Automation are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Publication SAFETY AT017B EN P July 2011 Supersedes pu...

Reviews: