Editing Drive Parameters
7-21
7.2
Display Parameters
Display parameters show information regarding the drive status. These parameters
are always read only.
d-00 Command Frequency
This parameter represents the
frequency that the drive is
commanded to output. This
Parameter Range:
0 to 240.0 (x.x Hz)
Running Access:
RO
command may come from any of the frequency sources selected by P-20 (Main Speed Reference) or P-21
(Alternate Speed Reference). The displayed value of this parameter can be scaled to other units by changing
P-62 (Speed Display Units).
d-01 Output Frequency
This parameter represents the output
frequency at terminals U, V, and W.
The displayed value of this parameter
can be scaled to other units by
Parameter Range:
0 to 240.0 (x.x Hz)
Running Access:
RO
changing P-62 (Speed Display Units).
d-02 Output Current
This parameter represents the output
current at terminals U, V, and W.
Parameter Range:
0 to 200% of rated current (x.x amps RMS)
Running Access:
RO
d-03 Bus Voltage
This parameter represents the DC
bus voltage level.
Parameter Range:
0 to 500 for 230 V drives;
0 to 1000 for 460 V drives.
Running Access:
RO
d-04 Fault Code
This parameter represents the fault
code for the last detected fault. Refer
to chapter 9 for troubleshooting code
Parameter Range:
alphanumeric code
Running Access:
RO
definitions.