18
Rockwell Automation Publication 750-AT006D-EN-P - January 2022
Chapter 1 Background
System C/U Select
10:905 [System C/U Select] allows either calculated or user-entered parameters to be applied to controller gains and filter bandwidths. It
also allows you to transfer calculated parameter values to user-entered parameter values so you can use them as a starting point for manual
tuning if desired.
lists the parameters that are applied to the controller when 10:905 [System C/U Select] = Calculated.
These parameters are auto-calculated as a function of 10:906 [System BW], 10:907 [System Damping], 10:901 [Load Ratio], and
10:902 [Load Coupling] during out-of-box and autotune calculations. You can also manually increase or decrease system bandwidth to
automatically adjust these parameters so that a single parameter, 10:906 [System BW], can be used to proportionally adjust all of these
control loop parameters.
lists the parameters that are applied to the controller when 10:905 [System C/U Select] = User Entered.
This selection allows you to enter values for these parameters directly.
shows how various parameters impact the
System C/U Selection. Autotune updates the parameters in red, which then triggers the automatic calculations upon any change of their
input parameters.
Table 2 - 10:905 [System C/U Select] = Calculated Parameters
Bandwidth Abbreviation
Parameter No.
Parameter Name
Description
Units
K
PP
10:1754
[c PReg Kp]
Position Loop Bandwidth
Hz
K
PI
10:1756
[c PReg Ki]
Position Integrator Bandwidth
Hz
K
VP
10:1955
[c VReg Kp]
Velocity Loop Bandwidth
Hz
K
VI
10:1957
[c VReg Ki]
Velocity Integrator Bandwidth
Hz
K
OP
10:2021
[c LdObs Kp]
Load Observer Bandwidth
Hz
K
OI
10:2023
[c LdObs Ki]
Load Observer Integrator Bandwidth
Hz
K
VFF
10:1760
[c Vel FF Gain]
Velocity Feed Forward Gain
%
K
AFF
10:1973
[c Accel FF Gain]
Acceleration Feed Forward Gain
%
—
10:2154
[c Trq LPF BW]
Torque Low Pass Filter Bandwidth
Hz
—
10:1002
[c VelFb LPF BW]
Velocity Feedback Low Pass Filter Bandwidth
Hz
—
10:1004
[c Vel Fb LPF Gn]
Velocity Feedback Low Pass Filter Gain
—
—
10:1008
[c AltVelFbLPF BW]
Alternate Velocity Feedback Low Pass Filter Bandwidth
Hz
—
10:1021
[c AltVelFBLPF Gn]
Alternate Velocity Feedback Low Pass Filter Gain
—
—
10:1928
[c Vel Comp Gain]
Velocity Compensation Gain
—
Table 3 - 10:905 [System C/U Select] = User Entered
Bandwidth Abbreviation
Parameter No.
Parameter Name
Description
Units
K
PP
10:1755
[u PReg Kp]
Position Loop Bandwidth
Hz
K
PI
10:1757
[u PReg Ki]
Position Integrator Bandwidth
Hz
K
VP
10:1956
[u VReg Kp]
Velocity Loop Bandwidth
Hz
K
VI
10:1958
[u VReg Ki]
Velocity Integrator Bandwidth
Hz
K
OP
10:2022
[u LdObs Kp]
Load Observer Bandwidth
Hz
K
OI
10:2024
[u LdObs Ki]
Load Observer Integrator Bandwidth
Hz
K
VFF
10:1761
[u Vel FF Gain]
Velocity Feed Forward Gain
%
K
AFF
10:1974
[u Accel FF Gain]
Acceleration Feed Forward Gain
%
—
10:2155
[u Trq LPF BW]
Torque Low Pass Filter Bandwidth
Hz
—
10:1003
[u VelFb LPF BW]
Velocity Feedback Low Pass Filter Bandwidth
Hz
—
10:1005
[u Vel Fb LPF Gn]
Velocity Feedback Low Pass Filter Gain
—
—
10:1009
[u AltVelFbLPF BW]
Alternate Velocity Feedback Low Pass Filter Bandwidth
Hz
—
10:1022
[u AltVelFBLPF Gn]
Alternate Velocity Feedback Low Pass Filter Gain
—
—
10:1929
[u Vel Comp Gain]
Velocity Compensation Gain
—