Install and Operate the Junction Boxes
Chapter 4
Figure 4 - Typical Connection of a First Generation MobileView Terminal to an IP20 Junction Box
Junction Box Cap
A cap is provided to cover the IP20 junction box opening when the cable is not
connected; see
. The cap helps protect the opening and its pin
connections from environmental elements.
Use one of the two bottom mounting screws of the junction box to attach the
tethered cable of the cap to the control cabinet.
1 2 3 4
LAN
5 6
6 5 4 3 2 1
7 8 9 1011
24V DC
GND
24V DC Power
Control Cabinet Wall
0.8…5 mm (0.03…0.2 in.) thickness
Connection Cable
See
for
connector descriptions.
57 mm (2.25 in)
Red dot on cable connector must align
with red dot on junction box.
Junction Box
Junction Box Cap
GND
GND
IMPORTANT
A 20-pin connection cable has a silver cable connector, as shown above. A
22-pin connection cable has a black cable connector, as shown on
.
You cannot use a 20-pin connection cable with second generation
MobileView terminals or either IP65 junction box.
For what MobileView devices work with a 22-pin connection cable, see
Summary of Contents for Allen-Bradley MobileView 2711T-VMBRACKET
Page 6: ...6 Rockwell Automation Publication 2711T UM001E EN P March 2019 Table of Contents Notes ...
Page 14: ...14 Rockwell Automation Publication 2711T UM001E EN P March 2019 Chapter 1 Features Notes ...
Page 100: ...100 Rockwell Automation Publication 2711T UM001E EN P March 2019 Index Notes ...
Page 101: ...Rockwell Automation Publication 2711T UM001E EN P March 2019 101 Index Notes ...
Page 102: ...102 Rockwell Automation Publication 2711T UM001E EN P March 2019 Index Notes ...
Page 103: ......