Rockwell Automation Publication 2711T-UM001E-EN-P - March 2019
27
Operate the Terminal
Chapter 3
Relocate the Connection Cable
Use the following tools to relocate the connection cable.
• 19 mm open-end wrench or spanner
• Torx T10 screwdriver
• 8 mm hex key
To relocate the cable, perform the following steps.
1.
Remove the plug with the 8 mm hex key from the side where you are going
to relocate the cable.
Set the plug aside.
2.
Unscrew the strain relief from the connector-cable mounting assembly
with the 19 mm open-end wrench or spanner.
3.
Disconnect the connector-cable mounting assembly from the cable
connection of the terminal with the 19 mm open-end wrench or spanner.
4.
Remove the back cover as detailed on
5.
Disconnect the terminal connections at S2, S3, and S4. See
for their locations.
6.
Gently pull the cable while you guide the three disconnected terminals out
through the cable channel and cable connection.
7.
to complete the cable relocation.
8.
Reinstall the plug with the 8 mm hex key in the cable connection from
which the cable was removed.
Torque the plug to 1.2 N•m (10.6 lb•in.).
TIP
on
to identify the components in steps 2 and 3.
IMPORTANT
Do not force the disconnected terminals through the channel, or wires
can be stripped from their connectors.
Summary of Contents for Allen-Bradley MobileView 2711T-VMBRACKET
Page 6: ...6 Rockwell Automation Publication 2711T UM001E EN P March 2019 Table of Contents Notes ...
Page 14: ...14 Rockwell Automation Publication 2711T UM001E EN P March 2019 Chapter 1 Features Notes ...
Page 100: ...100 Rockwell Automation Publication 2711T UM001E EN P March 2019 Index Notes ...
Page 101: ...Rockwell Automation Publication 2711T UM001E EN P March 2019 101 Index Notes ...
Page 102: ...102 Rockwell Automation Publication 2711T UM001E EN P March 2019 Index Notes ...
Page 103: ......