![Rockwell Automation Allen-Bradley Kinetix 350 Installation Instructions Manual Download Page 6](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-kinetix-350/allen-bradley-kinetix-350_installation-instructions-manual_1475827006.webp)
6
Kinetix 350 Single-axis EtherNet/IP Servo Drives
Rockwell Automation Publication 2097-IN008F-EN-P - September 2015
2.
Mount the Kinetix 350 drive to the cabinet subpanel with M4 (#6-32) steel machine
screws torqued to 1.1 N•m (9.8 lb•in).
For catalog numbers 2097-V33PR1-LM, 2097-V33PR3-LM, 2097-V33PR5-LM,
2097-V34PR3-LM, and 2097-V34PR5-LM that use an AC line filter, refer to the AC
Line Filter Installation Instructions, publication
, for the subpanel
mounting hole pattern.
Kinetix 350 Drive Mounting Dimensions
Cat. No.
Dimensions
mm (in.)
Cat. No.
Dimensions
mm (in.)
A
B
A
B
2097-V31PR0-LM
185.1 (7.29)
68.0 (2.68)
2097-V33PR3-LM
185.1 (7.29)
68.5 (2.70)
2097-V31PR2-LM
185.1 (7.29)
68.5 (2.70)
2097-V33PR5-LM
185.1 (7.29)
94.4 (3.72)
2097-V32PR0-LM
229.6 (9.04)
68.0 (2.68)
2097-V33PR6-LM
229.6 (9.04)
68.0 (2.68)
2097-V32PR2-LM
229.6 (9.04)
68.5 (2.70)
2097-V34PR3-LM
185.1 (7.29)
68.5 (2.70)
2097-V32PR4-LM
229.6 (9.04)
86.8 (3.42)
2097-V34PR5-LM
185.1 (7.29)
94.4 (3.72)
2097-V33PR1-LM
185.1 (7.29)
68.0 (2.68)
2097-V34PR6-LM
229.6 (9.04)
68.0 (2.68)
11.8
(0.46)
6.6
(0.26)
7.1
(0.28)
B
38.1
(1.5)
182
(7.18)
190
(7.50)
30.8
(1.21)
Ø 4.57
(0.18) 3x
A
238
(9.37)
61.0
(2.40)
9.7
(0.38)
5.0
(0.19)
Dimensions are in mm (in.).
2090-K2CK-D15M
Low-profile Connector Kit for Bulletin
2090 (flying-lead) Feedback Cable
More clearance below the connector kit is necessary to provide
the recommended cable-bend radius.