![Rockwell Automation Allen-Bradley Kinetix 350 Installation Instructions Manual Download Page 14](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-kinetix-350/allen-bradley-kinetix-350_installation-instructions-manual_1475827014.webp)
14
Kinetix 350 Single-axis EtherNet/IP Servo Drives
Rockwell Automation Publication 2097-IN008F-EN-P - September 2015
Kinetix 350 Drive Motor-power Wire Shielding
A motor-power ground clamp and two #6-32 x 1 screws are supplied with the Kinetix 350 drive.
Install the supplied motor-power ground clamp within 50…75 mm (2…3 in.) of the drive by
using the two #6-32 x 1 screws.
Motor Power Ground Clamp Installation
Motor Overload Protection
This servo drive uses solid-state motor overload protection that operates in accordance with
UL 508C. Motor overload protection algorithms (thermal memory) that can predict actual
motor temperature are based on operating conditions as long as control power is continuously
applied. However, when control power is removed, thermal memory is not retained.
This drive also provides an input for an external temperature sensor or thermistor device, which
is embedded in the motor, to support the UL requirement for motor overload protection.
50…75
(2…3)
50…75
(2…3)
34.0
(1.34)
25
(1.0)
12.7
(0.50)
If panel is painted, remove paint to provide
metal-to-metal contact.
Motor Power Ground Clamp
Dimensions are in mm (in.).