14
Industrial 15" Flat Panel Monitor
Publication 6185-5.1
4.
Connect the plug end of the AC power cord to the main outlet.
5.
Restore AC power to the outlet.
Connecting DC Power (DC Power Option)
The 6185-C Flat Panel Monitor with DC power option requires a DC
power supply providing 18 to 32V DC.
To connect DC power to the monitor:
1.
Turn off the main switch or breaker.
2.
Use the ground terminal of the monitor (below the power and T/S
connectors) to establish a chassis-to-earth ground connection.
Secure one end of a ground strap to the ground terminal. Connect
the other end of the ground strap to a good earth ground.
The ground terminal is an M5 screw.
ATTENTION: Chassis ground must be connected for
safe operation of the monitor. The DC screw terminals on
the monitor have a chassis ground pin. However, some
DC sources may not provide a proper ground path. If you
fail to ground the monitor properly, the setup may result
in personal injury from electrical shock or damage to the
equipment.
3.
Connect the +VDC wire to the “+V” screw terminal. Connect the -
VDC wire to the “-V” screw terminal. Connect the power source
ground wire to the GND screw terminal. Tighten down the screw
terminals.
4.
Restore DC power.