74
Rockwell Automation Publication 871FM-UM002A-EN-P - April 2017
Appendix B
Device Parameters
Diagnosis Tab
Parameter Name
Index
Hex (Dec)
Subindex
Hex (Dec)
Access
Default
Allowed Value
Data Type (Length)
Device Access Locks
Device Access Locks.Parameter (Write) Access
Locks
0x0C(12)
0x00(0)
RO
0=False
0=False
Boolean(RecordT)
bitOffset=0
Device Access Locks.Data Storage Lock
0x0C(12)
0x01(1)
RO
0=False
0=False
Boolean(RecordT)
bitOffset=1
Device Access Locks.Local Parameterization Lock
0x0C(12)
0x02(2)
RW
0=False
0=False
1=True
Boolean(RecordT)
bitOffset=2
Service Function
<Standard Command> Device Reset
0x02(2)
0x00(0)
WO
Button = “Device
Reset”
Button = 128
Button = “Device
Reset”
Button = 128
<Standard Command> Restore Factory
Settings
0x02(2)
0x82(130)
WO
Button = “Restore
Factory Settings”
Value = 130
UIntegerT
bitLength=8
.Locator Indicator
0x5E(94)
0x01(1)
RW
0= Disabled
0 = Disable(d)
1 = Enable(d)
Uinteger(RecordT)
bitLength=8
bitOffset=8
.LED Enable
5E(94)
0x0(2)
RW
1= Enabled
0 = Disable(d)
1 = Enable(d)
Uinteger(RecordT)
bitLength=8
bitOffset=0
Error Count
0x20(32)
0x00(0)
RO
—
—
UIntegerT
bitLength=16
Device Status
0x24(36)
0x00(0)
RO
0 = Device is OK
0 = Device is OK
1 = Maintenance
required
2 = Out of
specification
3 = Functional check
4 = Failure
UIntegerT
bitLength=8
Last Event
0x6E(110)
0x00(0)
RO
0
0…65,535
UIntegerT
bitLength=16
Operation Information
.Operating Time - Since Inception
0x5B(91)
0x01(1)
RO
Uinteger(RecordT)
bitLength=32
bitOffset=32
.Operating Time - Since Power Up
0x5B(91)
0x0(2)
RO
Uinteger(RecordT)
bitLength=32
bitOffset=0