Rockwell Automation Publication 871FM-UM002A-EN-P - April 2017
73
Device Parameters
Appendix B
Counter/Timer
Counter
Mode
0x5D(93)
0x01(1)
RW
0 = Disabled
0 = Disabled
1 = Enabled
Uinteger(RecordT)
bitLength=8
bitOffset=24
.Reset
0x5D(93)
0x02(2)
WO
—
1 = Reset
Uinteger(RecordT)
bitLength=8
bitOffset=16
.Counter
0x5D(93)
0x03(3)
RO
0
0…65,535
Uinteger(RecordT)
bitLength=16
bitOffset=0
Timer
.Mode
0x5C(92)
0x01(1)
RW
0 = Disabled
0 = Disabled
1 = Enabled
Uinteger(RecordT)
bitLength=8
bitOffset=40
.Reset
0x5C(92)
0x02(2)
WO
—
1 = Reset
Uinteger(RecordT)
bitLength=8
bitOffset=32
.DurationTriggered
0x5C(92)
0x03(3)
RO
0
0…4095
Uinteger(RecordT)
bitLength=12
.DurationNotTriggered
0x5C(92)
0x04(4)
RO
0
0…4095
Uinteger(RecordT)
bitLength=12
Data Mapping Cofiguration
.Mode
0x50(80)
0x01(1)
RW
0 = Triggered
Margin,
Proximity,Gain,
Signal,
0 =
TriggerMarginLowAlarmProximityAlarmExcessGainLevel
ReceivedSignalStrength,
1 =
TriggerMarginLowAlarmProximityAlarmExcessGainLevel
ContrastLevelTemperature,
2 =
TriggerMarginLowAlarmProximityAlarmExcessGainLevel
CounterValue,
3 =
TriggerMarginLowAlarmProximityAlarmOnDurationOff
Duration
Uinteger(RecordT)
bitLength=8
bitOffset=0
Parameter Tab
Parameter Name
Index
Hex (Dec)
Subindex
Hex (Dec)
Access
Default
Allowed Value
Data Type (Length)