Rockwell Automation Publication 856T-UM001B-EN-P - April 2021
59
Appendix C Device Parameters
Open Circuit Status
0x014D/333
—
Read-only
0
0…127
RecordT
(bit length = 8)
FALSE=0
Bit 0= Circuit 1 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 0)
FALSE=0
Bit 1= Circuit 2 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 1)
FALSE=0
Bit 2= Circuit 3 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 2)
FALSE=0
Bit 3= Circuit 4 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 3)
FALSE=0
Bit 4= Circuit 5 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 4)
FALSE=0
Bit 5= Circuit 6 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 5)
FALSE=0
Bit 6= Circuit 7 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 6)
Circuit Cycle Counter
0x0132/306
—
Read-only
0
0…4,294,967,296
RecordT
(bit length = 224)
Cycle counter (Circuit 1)
0x0132/306
0x0001/1
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 192)
Cycle counter (Circuit 2)
0x0132/306
0x0002/2
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 160)
Cycle counter (Circuit 3)
0x0132/306
0x0003/3
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 128)
Cycle counter (Circuit 4)
0x0132/306
0x0004/4
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 96)
Cycle counter (Circuit 5)
0x0132/306
0x0005/5
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 64)
Cycle counter (Circuit 6)
0x0132/306
0x0006/6
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 32)
Cycle counter (Circuit 7)
0x0132/306
0x0007/7
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 0)
Cycle Counter -Life time
0X014B/331
0
Read-only
0
0…4,294,967,296
RecordT
(bit length = 224)
Cycle counter-Life time
(Circuit 1)
0X014B/331
0x0001/1
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 192)
Cycle counter-Life time
(Circuit 2)
0X014B/331
0x0002/2
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 160)
Cycle counter-Life time
(Circuit 3)
0X014B/331
0x0003/3
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 128)
Cycle counter-Life time
(Circuit 4)
0X014B/331
0x0004/4
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 96)
Cycle counter-Life time
(Circuit 5)
0X014B/331
0x0005/5
Read-only
0
0…4,294,967,296
UIntegerT
(bit length = 32,
bit offset = 64)
Table 14 - Observation Tab (Continued)
Parameter Name
Index
(Hex/Dec)
Sub Index
(Hex/Dec)
Access
Default Value
Allowed Value
Data Type
(Length, Offset)
Summary of Contents for Allen-Bradley 856T-B24LC
Page 6: ...6 Rockwell Automation Publication 856T UM001B EN P April 2021 Table of Contents Notes ...
Page 72: ...72 Rockwell Automation Publication 856T UM001B EN P April 2021 Appendix D Device Status Notes ...
Page 80: ...80 Rockwell Automation Publication 856T UM001B EN P April 2021 Index Notes ...