58
Rockwell Automation Publication 856T-UM001B-EN-P - April 2021
Appendix C Device Parameters
.Module (Circuit 4)
0x0133/307
0x0004/4
Read-only
0
0…7
UIntegerT
(bit length = 8,
bit offset = 24)
.Module (Circuit 5)
0x0133/307
0x0005/5
Read-only
0
0…7
UIntegerT
(bit length = 8,
bit offset = 16)
.Module (Circuit 6)
0x0133/307
0x0006/6
Read-only
0
0…7
UIntegerT
(bit length = 8,
bit offset = 8)
.Module (Circuit 7)
0x0133/307
0x0007/7
Read-only
0
0…7
UIntegerT
(bit length = 8,
bit offset = 0)
Circuit Status
0x0136/310
—
Read-only
0
0...127
RecordT
(bit length =8)
OFF=0
Bit 0= Circuit 1 (ON/OFF)
ON= Bit value=1
OFF= Bit value= 0
BOOL
(bit length = 1,
bit offset = 0)
OFF=0
Bit 1= Circuit 2 (ON/OFF)
ON= Bit value=1
OFF= Bit value= 0
BOOL
(bit length = 1,
bit offset = 1)
OFF=0
Bit 2= Circuit 3 (ON/OFF)
ON= Bit value=1
OFF= Bit value= 0
BOOL
(bit length = 1,
bit offset = 2)
OFF=0
Bit 3= Circuit 4 (ON/OFF)
ON= Bit value=1
OFF= Bit value= 0
BOOL
(bit length = 1,
bit offset = 3)
OFF=0
Bit 4= Circuit 5 (ON/OFF)
ON= Bit value=1
OFF= Bit value= 0
BOOL
(bit length = 1,
bit offset = 4)
OFF=0
Bit 5= Circuit 6 (ON/OFF)
ON= Bit value=1
OFF= Bit value= 0
BOOL
(bit length = 1,
bit offset = 5)
OFF=0
Bit 6= Circuit 7 (ON/OFF)
ON= Bit value=1
OFF= Bit value= 0
BOOL
(bit length = 1,
bit offset = 6)
Short Circuit Status
0x014C/332
—
Read-only
0
0…127
RecordT
(bit length =8)
FALSE=0
Bit 0= Circuit 1 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 0)
FALSE=0
Bit 1= Circuit 2 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 1)
FALSE=0
Bit 2= Circuit 3 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 2)
FALSE=0
Bit 3= Circuit 4 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 3)
FALSE=0
Bit 4= Circuit 5 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 4)
FALSE=0
Bit 5= Circuit 6 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 5)
FALSE=0
Bit 6= Circuit 7 (TRUE/FALSE)
TRUE=1
FALSE=0
BOOL
(bit length = 1,
bit offset = 6)
Table 14 - Observation Tab (Continued)
Parameter Name
Index
(Hex/Dec)
Sub Index
(Hex/Dec)
Access
Default Value
Allowed Value
Data Type
(Length, Offset)