50
Rockwell Automation Publication 842E-UM002A-EN-P - November 2013
Chapter 6
Diagnostics and Troubleshooting
Table 2 - Encoder Fault Code Summary
Position
AxisFaultSubCode
Description
Hex value
Decimal
value
1 Over
temperature
sensor
Temperature value of the sensor is out of
range
0x1E
30
2
Light control reserve
LED current is incorrect
0x1D
0x2C
29
44
3
Frequency exceeded
Speed too high
(limit exceeded)
0x1F
31
4
Position error
Amplitude error Single
0x01
1
5
Position error
Amplitude error Multi
0x21
33
6
Position error
Vector length single
Vector length (Sin² + cos²)
0x1C
28
7
Position error
Vector length multi
Vector length (Sin² + cos²)
0x23
35
8
Position error
LY Digital Random Error and LY MFP5
Error
(single position)
0x20
0x2A
32
42
9
Position error
Position Multi turn error,
synchronization
(MA-Single, Init)
0x22
0x2B
34
43
10
Position error
Position Multi turn error, internal
Interface
0x25
37
11
Position error
SSI Failure - internal communication
interface
0xFF
255
12
Startup error
Startup error
0x18
0x02
24
2
13
Position or Memory error
Memory or EEPROM CheckSum error
0x06
6
14
Memory error
Memory or EEPROM
I2C error
0x05
5
15
Diagnostic error
This Flag is set if the encoder detects a
diagnostic error.
0x2F
47
Fault code type
Description
NODE FLTxx
Exceptions that prevent normal operation of the encoder.
NODE ALARM xx
Exceptions that prevent normal operation of the encoder, but do not result in any
action other than reporting the alarm to the controller.
INHIBIT Mxx
Exceptions that prevent normal operation and indicate whenever the encoder is
active.