4
Rockwell Automation Publication 42G-TD001C-EN-P - June 2022
Series 9000 Photoelectric Sensors Specifications Technical Data
10…30V DC
Visible red
660 nm
0.050…1.5 m
(0.16…5 ft)
NPN and PNP
Standard ON/OFF
Linear Adjustment
42GLP-9000-QD
Standard ON/OFF
Teach Push Button
42GSP-9000-QD
Standard ON/OFF
42GRP-9000-QD
Timing
42GTP-9000-QD
10…55V DC;
20…40V AC
SPDT EM relay
Standard ON/OFF
42GRP-9001-QD
Timing
42GTP-9001-QD
70…264V AC/DC
Standard ON/OFF
42GRP-9002-QD
Timing
42GTP-9002-QD
N-MOSFET
Standard ON/OFF
42GRP-9003-QD
Timing
42GTP-9003-QD
10…30V DC
Class 1
Laser
1…800 mm
(0.03…31.5 in.)
NPN and PNP
Standard ON/OFF
42GRP-92L0-QD
105…132V AC
SPDT EM relay
42GRP-92L2-QD
10…30V DC
Infrared
880 nm
0.050…3.04 m
(0.16…10 ft)
NPN and PNP
Standard ON/OFF
42GRP-9040-QD
Timing
42GTP-9040-QD
10…55V DC;
20…40V AC
SPDT EM relay
Standard ON/OFF
42GRP-9041-QD
Timing
42GTP-9041-QD
70…264V AC/DC
Standard ON/OFF
42GRP-9042-QD
Timing
42GTP-9042-QD
70…264V DC;
40…264V AC
N-MOSFET
Standard ON/OFF
42GRP-9043-QD
Timing
42GTP-9043-QD
10…30V DC
0.050…4.2 m
(0.16…14 ft)
NPN and PNP
Standard ON/OFF
42GRP-9070-QD
70…264V AC/DC
50.8 mm…4.2 m
(2 in.…14 ft)
SPDT EM relay
Standard ON/OFF
42GRP-9072-QD
10…30V DC
Visible red
660 nm
Depends on
fiber-optic cable
NPN and PNP
Standard ON/OFF
42GRF-9100-QD
Timing
42GTF-9100-QD
10…55V DC;
20…40V AC
SPDT EM relay
Standard ON/OFF
42GRF-9101-QD
Timing
42GTF-9101-QD
70…264V AC/DC
Standard ON/OFF
42GRF-9102-QD
Timing
42GTF-9102-QD
N-MOSFET
Standard ON/OFF
42GRF-9103-QD
Timing
42GTF-9103-QD
10…30V DC
Infrared
880 nm
Depends on
fiber-optic cable
NPN and PNP
Standard ON/OFF
42GRF-9000-QD
Timing
42GTF-9000-QD
10…55V DC;
20…40V AC
SPDT EM relay
Standard ON/OFF
42GRF-9001-QD
Timing
42GTF-9001-QD
70…264V AC/DC
Standard ON/OFF
42GRF-9002-QD
Timing
42GTF-9002-QD
N-MOSFET
Standard ON/OFF
42GRF-9003-QD
Timing
42GTF-9003-QD
Recommended DC micro (M12) quick-disconnect cordset, straight, 4-pin, 2 m (6.6 ft)
889D-F4AC-2
Recommended DC pico (M8) quick-disconnect cordset, straight, 4-pin, 2 m (6.6 ft)
889D-F4AB-2
(1)
Connection Options: The -QD suffix describes a 4-pin DC micro (M12) integral QD for DC models, a 5-pin mini QD for SPDT EM Relay models, and a 4-pin mini (M12) integral QD for N-MOSFET
models.
For additional connection options:
- Remove the -QD suffix for a 2 m (6.6 ft) cable without QD (Example: 42GRU-9200).
- For NPN and PNP models replace the -QD suffix with a -QD1 for a 4-pin mini-integral QD (for example, 42GRU-9200-QD1). For N-MOSFET models, replace the -QD suffix with a -QD1 for a 4-pin
AC micro (M12) integral QD (for example, 42GRU-9203-QD1).
- See ProposalWorks™ for available connection options in 600V 2 m (6.6 ft) cables.
Table 6 - Product Selection (Continued)
Sensing Mode
Operating Voltage
Light
Source
Sensing
Distance
Output Type
Sensor Type
Cat. No.
(1)
Object
to be
Sensed
Diffuse
Object
to be
Sensed
Small Aperture Fiber Optic
Object
to be
Sensed
Large Aperture Fiber Optic