About the Feedback Converter Kit

This kit is designed for use with Allen-Bradley® 2090-Series motor feedback cables and provides 
wire terminations for 10 Hiperface encoder signals. The Hiperface encoder signals are converted 
into compatible digital-servo-link (DSL) feedback signals. You must wire the 10-pin converter 
kit connector and assemble the connector housing with the cable shield and cable jacket properly 
positioned.

Prepare the Cables

To prepare your existing Bulletin 2090 cables for use with the feedback converter kit, some 
preparation is necessary so that the cable shield, conductor lengths, and strip lengths are correct. 
Make sure your feedback cable preparation follows these guidelines:

• Trim the shield flush so that no strands can cause a short to adjacent terminals.

• Measure the conductor lengths so they are long enough to provide a service loop.

• Remove just enough insulation from each conductor to provide the proper strip length.

Feedback Cable

12.0 (0.5)

5.0 (0.2)

115 (4.5)

103 (4.0)

Cable Jacket

Cable Shield

Shield Clamp

Cable Positioned Where Cover