Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
153
Chapter 9 Connected Components Workbench Software
Download and Upload
Configurations
Three essential steps are required to change a configuration in the light
curtain:
1. Download the project to the light curtain.
2. Upload the project from the light curtain.
3. Lock the configuration.
starts the step-by-step process for changing the configuration in the
light curtain.
1. Go offline (disconnected).
2. Complete the configuration.
3. Click Download.
Figure 148 - Configure Light Curtain Offline
shows that the download was a success. The downloaded and
uploaded CRC are identical.
4. Click OK.
Figure 149 - Download Successful
Table 71 - Maximum Object Size Table
Select Maximum Object Size
If the object height is smaller than…
Finger Resolution [mm (in.)]
Hand Resolution [mm (in.)]
1
5.47 (0.22)
13.06 (0.51)
2
14.85 (0.58)
31.82 (1.25)
3
24.23 (0.95)
50.58 (1.99)
4
33.61 (1.32)
69.34 (2.73)
5
42.99 (1.69)
88.10 (3.47)
6
52.37 (2.06)
106.86 (4.21)
7
61.75 (2.43)
125.62 (4.95)
8
71.13 (2.80)
144.38 (5.68)
9
80.51 (3.17)
163.14 (6.42)
10
89.89 (3.54)
181.90 (7.16)