     Micro810 12 Point Programmable Controllers

Publication 2080-IN006A-EN-P - September 2010

North American Hazardous Location Approval

The following modules are North American Hazardous Location approved: 
2080-LC10-12AWA, 2080-LC10-12QWB, 2080-LC10-12QBB, 2080-LC10-12DWD  

 

 

   

 

The following information applies when 
operating this equipment in hazardous 
locations:

Informations sur l’utilisation de cet 
équipement en environnements 
dangereux:

Products marked "CL I, DIV 2, GP A, B, C, D" are 
suitable for use in Class I Division 2 Groups A, B, C, 
D, Hazardous Locations and nonhazardous locations 
only. Each product is supplied with markings on the 
rating nameplate indicating the hazardous location 
temperature code. When combining products within 
a system, the most adverse temperature code 
(lowest "T" number) may be used to help determine 
the overall temperature code of the system. 
Combinations of equipment in your system are 
subject to investigation by the local Authority Having 
Jurisdiction at the time of installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne 
conviennent qu'à une utilisation en environnements 
de Classe I Division 2 Groupes A, B, C, D dangereux et 
non dangereux. Chaque produit est livré avec des 
marquages sur sa plaque d'identification qui indiquent 
le code de température pour les environnements 
dangereux. Lorsque plusieurs produits sont combinés 
dans un système, le code de température le plus 
défavorable (code de température le plus faible) peut 
être utilisé pour déterminer le code de température 
global du système. Les combinaisons d'équipements 
dans le système sont sujettes à inspection par les 
autorités locales qualifiées au moment de 
l'installation.

WARNING

EXPLOSION HAZARD

Do not disconnect equipment 
unless power has been 
removed or the area is known 
to be nonhazardous. 

Do not disconnect connections 
to this equipment unless power 
has been removed or the area 
is known to be nonhazardous. 
Secure any external 
connections that mate to this 
equipment by using screws, 
sliding latches, threaded 
connectors, or other means 
provided with this product.

Substitution of any component 
may impair suitability for Class 
I, Division 2.

If this product contains 
batteries, they must only be 
changed in an area known to 
be nonhazardous.

AVERTISSEMENT

RISQUE D’EXPLOSION

Couper le courant ou s'assurer 
que l'environnement est classé 
non dangereux avant de 
débrancher l'équipement.

Couper le courant ou s'assurer 
que l'environnement est classé 
non dangereux avant de 
débrancher les connecteurs. 
Fixer tous les connecteurs 
externes reliés à cet 
équipement à l'aide de vis, 
loquets coulissants, 
connecteurs filetés ou autres 
moyens fournis avec ce produit.

La substitution de tout 
composant peut rendre cet 
équipement inadapté à une 
utilisation en environnement de 
Classe I, Division 2.

S'assurer que l'environnement 
est classé non dangereux avant 
de changer les piles.

Summary of Contents for 2080-LC10-12AWA

Page 1: ... aparece acima para encontrar e fazer download da publicação IT Questa pubblicazione è disponibile in Italiano in formato PDF Per scaricarla collegarsi al sito Web indicato sopra ZH DE Diese Publikation ist als PDF auf Deutsch verfügbar Gehen Sie auf die oben genannte Web Adresse um nach der Publikation zu suchen und sie herunterzuladen ZC ES Esta publicación está disponible en español como PDF Di...

Page 2: ...r installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is...

Page 3: ...or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 V0 or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition to this pu...

Page 4: ...s produits sont combinés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation WARNING EXPLOSION HAZARD Do not disconnect equipment unless power h...

Page 5: ...nt connection If you connect or disconnect the USB cable with power applied to this module or any device on the USB network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding The USB port is a nonincendive field wiring connection for Class I Division2 Groups A B C and D Exposure t...

Page 6: ...or other sensitive areas This product is intended to be mounted to a well grounded mounting surface such as a metal panel Additional grounding connections from the power supply s mounting tabs or DIN rail if used are not required unless the mounting surface cannot be grounded Refer to Industrial Automation Wiring and Grounding Guidelines Allen Bradley publication 1770 4 1 for additional informatio...

Page 7: ...r supply Controller Overview Status Indicator Controller Description Description Description 1 Status indicator 4 USB port for use with USB Adapter only 2 Input terminal block 5 DIN rail mounting latch 3 Mounting screw hole mounting foot 6 Output connectors State During Normal Operation During Firmware Update or Program Data Transfer Off No power applied to device or in Fault mode No power applied...

Page 8: ... objects such as enclosure walls wireways and adjacent equipment Allow 50 8 mm 2 in of space on all sides for adequate ventilation DIN Rail Mounting The module can be mounted using the following DIN rails 35 x 7 5 x 1 mm EN 50 022 35 x 7 5 Before mounting the module on a DIN rail use a flat blade screwdriver in the DIN rail latch and pry it downwards until it is in the unlatched position 1 Hook th...

Page 9: ...g screws 1 Place the controller against the panel where you are mounting it Make sure the controller is spaced properly 2 Mark drilling holes through the mounting screw holes and mounting feet then remove the controller 3 Drill the holes at the markings then replace the controller and mount it Leave the protective debris strip in place until you are finished wiring the controller and any other dev...

Page 10: ...01 O 00 CM2 O 02 1 2 3 4 5 6 7 8 CM3 45059 DC24 COM0 DC24 I 00 DC24 I 01 I 02 1 2 3 4 5 6 7 8 9 10 11 12 I 03 I 04 I 06 I 05 I 07 CM0 CM1 O 03 O 01 O 00 CM2 O 02 1 2 3 4 5 6 7 8 CM3 45059 Input Terminal Block Output Terminal Block CM0 CM1 O 03 O 01 O 00 CM2 O 02 1 2 3 4 5 6 7 8 CM3 45059 2080 LC10 12QBB Input Terminal Block Output Terminal Block 45056 DC24 COM0 DC24 I 00 DC24 I 01 I 02 1 2 3 4 5 6...

Page 11: ...2 12V DC Class 2 12 24V DC Class 2 Power consumption 5V A 5 W I O rating Input 120 240V AC 8 4V A Output C300 R150 8A 250V AC General Use Input 24V DC 8 mA Output C300 R150 8A 250V AC General Use Input 12V DC 8 mA Output C300 R150 8A 250V AC General Use Input 24V DC 8 mA Output 24V DC 1A 25 C 24V DC 0 5A 55 C Shipping weight approx 0 203 kg 0 448 lb Wire size 0 32 2 1 mm 22 14 AWG solid copper wir...

Page 12: ...ding Guidelines publication 1770 4 1 Non isolated AC Inputs 2080 LC10 12AWA Attribute Value On state voltage nom 120 240 V AC On state voltage min 79 V AC On state voltage max 265 V AC Off state voltage max 40 V AC Operating frequency nom 50 60 Hz Input impedence 423 7 kΩ Operating frequency 47 63 Hz DC Inputs 2080 LC10 12QWB 12QBB 12DWD Inputs 0 through 3 Attribute Non isolated shared with analog...

Page 13: ...ull scale 2 with calibration 25 55 C 77 131 F Noise rejection 50 60 Hz Common mode rejection 40 dB DC to 60 Hz with Smoothing filter Nominal impedance 14 1 kΩ non isolated DC Output 2080 LC10 12QBB Attribute Value User supply voltage min 10 V DC User supply voltage max 26 4V DC On state voltage drop 1V max load current 2 5V max surge current Current ratings 0 5A 55 C max 1 0A 30 C max 1 0 mA min S...

Page 14: ...ating Cold IEC 60068 2 2 Test Bb Unpackaged Non operating Dry Heat IEC 60068 2 14 Test Na Unpackaged Non operating Thermal Shock 40 85 C 40 185 F Relative humidity IEC 60068 2 30 Test Db Unpackaged Damp Heat 5 95 non condensing Vibration IEC 60068 2 6 Test Fc Operating 2 g 10 500 Hz Shock operating IEC 60068 2 27 Test Ea Unpackaged Shock 30 g Shock nonoperating IEC 60068 2 27 Test Ea Unpackaged Sh...

Page 15: ...erruptions for 250 periods on AC supply ports Certifications Certification when product is marked 1 1 See the Product Certification link at http www ab com for Declaration of Conformity Certificates and other certification details Value c UL us UL Listed Industrial Control Equipment certified for US and Canada See UL File E322657 UL Listed for Class I Division 2 Group A B C D Hazardous Locations c...

Page 16: ...etting your product up and running New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Allen Bradley Rockwell Automation Micro810 and TechConnect are trademarks of Rockwell Automation Inc Tradema...

Reviews: