background image

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its 
products. At 

http://support.rockwellautomation.com

, you can find technical manuals, a 

knowledge base of FAQs, technical and application notes, sample code and links to software 
service packs, and a MySupport feature that you can customize to make the best use of these 
tools.

For an additional level of technical phone support for installation, configuration and 
troubleshooting, we offer TechConnect support programs. For more information, contact 
your local distributor or Rockwell Automation representative, or visit 
h

ttp://support.rockwellautomation.com

.

Installation Assistance

If you experience a problem within the first 24 hours of installation, please review the 
information that's contained in this manual. You can also contact a special Customer Support 
number for initial help in getting your product up and running.

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when 
shipped from the manufacturing facility. However, if your product is not functioning and 
needs to be returned, follow these procedures.

Allen-Bradley, Rockwell Automation, Micro810, and TechConnect are trademarks of Rockwell Automation, Inc. 
Trademarks not belonging to Rockwell Automation are property of their respective companies.

United States

1.440.646.3434
Monday – Friday, 8 a.m. – 5 p.m. EST

Outside United States

Please contact your local Rockwell Automation representative for any technical 
support issues.

United States

Contact your distributor. You must provide a Customer Support case number (call the 
phone number above to obtain one) to your distributor in order to complete the return 
process.

Outside United States

Please contact your local Rockwell Automation representative for the return 
procedure.

Publication 2080-IN006A-EN-P - September 2010

PN 953203-31

Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Printed in Singapore.

Summary of Contents for 2080-LC10-12AWA

Page 1: ... aparece acima para encontrar e fazer download da publicação IT Questa pubblicazione è disponibile in Italiano in formato PDF Per scaricarla collegarsi al sito Web indicato sopra ZH DE Diese Publikation ist als PDF auf Deutsch verfügbar Gehen Sie auf die oben genannte Web Adresse um nach der Publikation zu suchen und sie herunterzuladen ZC ES Esta publicación está disponible en español como PDF Di...

Page 2: ...r installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is...

Page 3: ...or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 V0 or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition to this pu...

Page 4: ...s produits sont combinés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation WARNING EXPLOSION HAZARD Do not disconnect equipment unless power h...

Page 5: ...nt connection If you connect or disconnect the USB cable with power applied to this module or any device on the USB network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding The USB port is a nonincendive field wiring connection for Class I Division2 Groups A B C and D Exposure t...

Page 6: ...or other sensitive areas This product is intended to be mounted to a well grounded mounting surface such as a metal panel Additional grounding connections from the power supply s mounting tabs or DIN rail if used are not required unless the mounting surface cannot be grounded Refer to Industrial Automation Wiring and Grounding Guidelines Allen Bradley publication 1770 4 1 for additional informatio...

Page 7: ...r supply Controller Overview Status Indicator Controller Description Description Description 1 Status indicator 4 USB port for use with USB Adapter only 2 Input terminal block 5 DIN rail mounting latch 3 Mounting screw hole mounting foot 6 Output connectors State During Normal Operation During Firmware Update or Program Data Transfer Off No power applied to device or in Fault mode No power applied...

Page 8: ... objects such as enclosure walls wireways and adjacent equipment Allow 50 8 mm 2 in of space on all sides for adequate ventilation DIN Rail Mounting The module can be mounted using the following DIN rails 35 x 7 5 x 1 mm EN 50 022 35 x 7 5 Before mounting the module on a DIN rail use a flat blade screwdriver in the DIN rail latch and pry it downwards until it is in the unlatched position 1 Hook th...

Page 9: ...g screws 1 Place the controller against the panel where you are mounting it Make sure the controller is spaced properly 2 Mark drilling holes through the mounting screw holes and mounting feet then remove the controller 3 Drill the holes at the markings then replace the controller and mount it Leave the protective debris strip in place until you are finished wiring the controller and any other dev...

Page 10: ...01 O 00 CM2 O 02 1 2 3 4 5 6 7 8 CM3 45059 DC24 COM0 DC24 I 00 DC24 I 01 I 02 1 2 3 4 5 6 7 8 9 10 11 12 I 03 I 04 I 06 I 05 I 07 CM0 CM1 O 03 O 01 O 00 CM2 O 02 1 2 3 4 5 6 7 8 CM3 45059 Input Terminal Block Output Terminal Block CM0 CM1 O 03 O 01 O 00 CM2 O 02 1 2 3 4 5 6 7 8 CM3 45059 2080 LC10 12QBB Input Terminal Block Output Terminal Block 45056 DC24 COM0 DC24 I 00 DC24 I 01 I 02 1 2 3 4 5 6...

Page 11: ...2 12V DC Class 2 12 24V DC Class 2 Power consumption 5V A 5 W I O rating Input 120 240V AC 8 4V A Output C300 R150 8A 250V AC General Use Input 24V DC 8 mA Output C300 R150 8A 250V AC General Use Input 12V DC 8 mA Output C300 R150 8A 250V AC General Use Input 24V DC 8 mA Output 24V DC 1A 25 C 24V DC 0 5A 55 C Shipping weight approx 0 203 kg 0 448 lb Wire size 0 32 2 1 mm 22 14 AWG solid copper wir...

Page 12: ...ding Guidelines publication 1770 4 1 Non isolated AC Inputs 2080 LC10 12AWA Attribute Value On state voltage nom 120 240 V AC On state voltage min 79 V AC On state voltage max 265 V AC Off state voltage max 40 V AC Operating frequency nom 50 60 Hz Input impedence 423 7 kΩ Operating frequency 47 63 Hz DC Inputs 2080 LC10 12QWB 12QBB 12DWD Inputs 0 through 3 Attribute Non isolated shared with analog...

Page 13: ...ull scale 2 with calibration 25 55 C 77 131 F Noise rejection 50 60 Hz Common mode rejection 40 dB DC to 60 Hz with Smoothing filter Nominal impedance 14 1 kΩ non isolated DC Output 2080 LC10 12QBB Attribute Value User supply voltage min 10 V DC User supply voltage max 26 4V DC On state voltage drop 1V max load current 2 5V max surge current Current ratings 0 5A 55 C max 1 0A 30 C max 1 0 mA min S...

Page 14: ...ating Cold IEC 60068 2 2 Test Bb Unpackaged Non operating Dry Heat IEC 60068 2 14 Test Na Unpackaged Non operating Thermal Shock 40 85 C 40 185 F Relative humidity IEC 60068 2 30 Test Db Unpackaged Damp Heat 5 95 non condensing Vibration IEC 60068 2 6 Test Fc Operating 2 g 10 500 Hz Shock operating IEC 60068 2 27 Test Ea Unpackaged Shock 30 g Shock nonoperating IEC 60068 2 27 Test Ea Unpackaged Sh...

Page 15: ...erruptions for 250 periods on AC supply ports Certifications Certification when product is marked 1 1 See the Product Certification link at http www ab com for Declaration of Conformity Certificates and other certification details Value c UL us UL Listed Industrial Control Equipment certified for US and Canada See UL File E322657 UL Listed for Class I Division 2 Group A B C D Hazardous Locations c...

Page 16: ...etting your product up and running New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Allen Bradley Rockwell Automation Micro810 and TechConnect are trademarks of Rockwell Automation Inc Tradema...

Reviews: