MULTI FIXTURE USE
Master/Slave
Synchronous Mode
1. Hang all the fixtures.
2. Connect all fixtures via the DMX IN/DMX OUT ports.
3. Connect to power source and turn-on all fixtures.
4. Set any fixture to Ch5 (7 channel mode) or Ch13 (15 channel mode), set the
DMX value (237 – 246), and wait for o1 to 2 seconds.
5. Set the value back to 0 and wait 1 to 2 seconds. Repeat for all fixtures.
6. Now all fixtures should be in synchronous mode.
7. To add more fixtures, simply repeaty the steps above.
OPERATION
Use the MENU button to enter the settings menu. Use the UP and DOWN
buttons to select the desired setting and set their values. Press ENTER button
to save your selection. Please note that the unit can automatically identify DMX
mode and Master/Slave mode.
Slave signal
DMX signal
1. Hang all the fixtures.
2. Connect all fixtures via the DMX IN/DMX OUT ports.
3. Connect to power source and turn-on all fixtures.
4. Adjust as DMX mode (d001) on the panel display.
5. Choose one fixture and press any button to set it as the Master fixture. Once
the master has been chosen, all other fixtures become slaves.
6. The current Master fixture will always be the master for future use. To choose
another fixture as the master, change the DMX mode to d001 on the current
master fixture. Now repeat step 5 to set the desired fixture as the master.