4
The COMPARE button may also be used to simultaneously compare multiple
modified parameters under the same effect heading (i.e. Reverb, Mixer, etc.) to the
stored values. To do so, turn to the effect heading where the modified parameters are
located and press the COMPARE button. When the STORE LED is off, the stored
parameter values are currently active. When the STORE LED is lit, the modifed
values are active.
If a knob is turned or a button is pressed which changes the effect heading when the
stored parameters are active (STORE LED off), any modified parameter values
under that heading will be lost. This is also true if a MIDI control change is received
while the stored parameters are active.
(7) PARAMETER ADJUST control:
This control is used to adjust the displayed parameter value. When the parameter is
changed from its original value, the LED above the STORE button will light until
either (a) the new value is stored, (b) a new preset is selected or (c) the parameter is
returned to its original value.
(8) STORE button:
This button is used to store values into the Intellifex LTD memory when modified.
See Chapter 8, section C, "Storing Modified Parameters" for more information.
(9) PARAMETER SELECT control:
When monitoring parameter values, this control will scroll through the available
parameters under the current effect heading.
In the "TITLE EDlT" function, this control will scroll through the available
characters in the title that may be edited.
(10) FUNCTION SELECT control:
This control allows access to each function of the Intellifex LTD. Depending on
which configuration the current preset is built upon, these functions may include:
Preset Select
Reverb Parameters
Mixer Parameters
Title Edit
HUSH Parameters
MIDI Controller Mapping
Chorus Parameters
MIDI Program Mapping
Pitch Shift Parameters
MIDI Channel
Delay Parameters
Ducker Parameters
Factory Restore
MIDI Dump/Load
(11) BYPASS button:
When pressed, the LED is lit and all effects are bypassed.