SECTION 4 — PROGRAMMING
SSC-500 Hydraulic Press Solid-State Control
Rockford Systems, LLC
32
Call: 1-800-922-7533
(Continued on next page.)
LUBE FLT
HIGH LUBE FLT
LOW LUBE FLT
LOW LUBE LEVEL
MAIN MTR OL FLT
LUBE MTR OL FLT
AUX MTR OL FLT
GUARD OPEN FLT
REAR GUARD FLT
LEFT GUARD FLT
RIGHT GUARD FLT
FEEDER FLT
LOAD MONITOR FLT
SAFETY BLK FLT
DIE PROTECTION FLT
STOCK BUCKLE
END OF STOCK
EXTRN CNTRL FLT
N.O.
N.C.
ENTER
Press ENTER to
select the Logic
E-STOP
T-STOP
ENTER
Press ENTER to select the
Stop Type and return to the
MAIN MENU
INPUT #X
Selects the Program Menu Item
INPUT #X (X = 1, 2, 3, or 4 )
ENTER
Press the DOWN and UP
arrows to scroll through the
list of messages
MAIN
MENU
ENTER
Press ENTER to assign
the fault message
Press the DOWN and UP
arrows to change the logic
Press the DOWN and UP
arrows to change the stop type
OFF
Figure 4.15
INPUT #1, 2, 3, 4 Programming Flowchart*
USER INPUTS
(continued)
INPUT #1 (2, 3, 4)
Select the
PROG
position on the Program/Run selector switch.
Press the
t
and
s
buttons on the keypad to scroll through the
program options. Press
ENTER
when the LCD displays
INPUT # 1
.
Programming is the same for all four inputs.
The display now reads:
X FLT
Where
X FLT
is a fault message from the list in Figure 4.8 on page 28.
Press the
t
and
s
buttons on the keypad to scroll through the list of
fault messages. Press
ENTER
to program the fault message displayed.
The display now reads one of the following:
OFF
(Disabled)
N.O.
(Normally Open)
N.C.
(Normally Closed)
Press the
t
and
s
buttons on the keypad to change the logic
options. Press
ENTER
to program the input logic displayed.
Next, the LCD displays one of the following:
E-STOP
(Emergency Stop)
T-STOP
(Top Stop)
Press the
t
and
s
buttons on the keypad to change the stop type.
Press
ENTER
to program the input logic displayed and return to the
main menu level. The LCD displays
INPUT #1
.
Function
The user inputs can be programmed to monitor and diagnose common
problems with auxiliary equipment on the machine. Examples are main
clutch/brake air pressure, dual solenoid pressure switch, lube system
pressure or level switches, motor overloads, load monitors, stock
buckle, and end of stock sensors. Refer to the wiring diagram sheet 2
for information on wiring the inputs to the proper terminals.
*Note: If block valve monitoring is enabled, only three (3) user inputs
will be available.
Setting Type:
List Selection
Range:
NA
Factory Setting:
C/B Air Flt/Off/E-Stop