SECTION 4 — PROGRAMMING
SSC-500 Hydraulic Press Solid-State Control
Rockford Systems, LLC
28
Call: 1-800-922-7533
(Continued on next page.)
DECOMPRESS TMR ms
XXX
ENTER
Selects the Program Menu
Item
DECOMPRESS TMR ms
ENTER
XXX = Current DECOMPRESS
timer value
Press the DOWN and UP
Program the
DECOMPRESS
time and return to Main Menu
MAIN
MENU
arrows to decrease or
increase the current timer
BOTTOM DWELL ms
Select the
PROG
position on the Program/Run selector switch.
Press the
t
and
s
buttons on the keypad to scroll through the
program options. Press
ENTER
when the LCD displays
BOT DWELL ms
.
The display now reads:
XXXX
Where
XXXX
= a number between 0 and 60 seconds
Press the
t
and
s
buttons on the keypad to increase or decrease
the
BOTTOM DWELL
timer. Pressing and holding the arrow keys will
change the numbers at a rapid rate. Press
ENTER
to program the
BOTTOM DWELL
timer to the displayed time and return to the main
menu level. The LCD again displays
BOTTOM DWELL ms
.
Function
When the ram reaches the BOS limit switch, the down valve stays
energized until the bottom dwell timer (if programmed) times out. Once
the time runs out, the up valve will energize, returning the ram to the
TOS limit switch.
DECOMPRESS TIMER
Select the
PROG
position on the Program/Run selector switch.
Press the
t
and
s
buttons on the keypad to scroll through the
program options. Press
ENTER
when the LCD displays
Decompress
.
The display now reads:
XXX
Where
XXX
= a number between 025 and 250 ms.
Press the
t
and
s
buttons on the keypad to increase or decrease
the
Decompress
timer. Pressing and holding the arrow keys will
change the numbers at a rapid rate. Press
ENTER
to program the
Decompress
timer to the displayed time and return to the main menu
level. The LCD again displays
Decompress Tmr ms
.
Function
When the ram reaches the BOS limit switch, the down valve will
deenergize causing the decompress timer (if programmed) to time out.
Once the time runs out, the up valve will energize, returning the ram
to the TOS limit switch.
Figure 4.8
DECOMPRESS TIMER Programming Flowchart
Setting Type:
Time - ms (milliseconds)
Range:
025 - 250 ms
Factory Setting:
025
Figure 4.7
BOTTOM DWELL Programming Flowchart
BOTTOM DWELL ms
XXXX
ENTER
Selects the Program Menu
Item
BOT DWELL ms
ENTER
XXXX =
Current
BOTTOM DWELL
timer value
Press the DOWN and UP
Program the
BOTTOM DWELL
time and return to Main Menu
MAIN
MENU
arrows to decrease or
increase the current timer
Setting Type:
Time - seconds
Range:
0 - 60 ms
Factory Setting:
0 seconds