The Eliminator

Rotogauge Replacement 

For LP Gas & NH

3

Service

P6293 Series

Materials of Construction*

Head, Gears, Gear Housing, Cross Stud, Bearings

& Float

Stainless steel.

Centershaft, Float Rod, & Support Tube

Stainless steel.

Drive Magnet

Alnico.

Gasket

Spiral wound, teflon filled, stainless steel.

Adapter

Cold-rolled steel.

Counterweight

Stainless steel.

Note:

For threaded gauge installation instructions see MS-516.

When or der ing, specify:

1.

Model number.

2.

Tank I.D.

WARNING:

Carefully ensure that gauge and adapter are

ad e quate ly pro tect ed from dam age that might cause leak age

of tank contents.

* Materials and specifications are subject to change with out notice. 

Pressure ratings sub ject to change due to tem per a ture and other en vi ron men tal considerations.

Adapter 0022-05276

1" NPT

75°

75°

15°

15° 

Support Tube

As Required ± 

1

8

"

Float Rod

As Required ± 

1

8

"

The Measure of Excellence

11616 Harry Hines Blvd. 

P.O. Box 29242 

Dallas, TX 75229 

(972) 241-2161 • 

FAX

(972) 620-3374

Website

http://www.rochestergauges.com 

E-mail

[email protected]

05/17/13

WARNING:

Determine and in stall the appropriate replacement gauge based on system re quire ments. The gasket type

supplied may not be suitable for all applications and for those applications other gas ket materials may be available. The in -

for ma tion contained here in is in tend ed for guideline use only and the suitability of any part for a particular ap pli ca tion must

be de ter mined by the user prior to installation. Improper gauge or gas ket selection or application may re sult in seal failure

and sub se quent release of tank contents.

WARNING: 

Even if gauge registers empty, tank may contain high pressure and flammable gas. Do not remove gauge or other

pressure containing fittings unless precautions against release of tank contents have been taken. A hazard of fire or explosion

may exist if proper methods are not used when removing or installing the gauge or gasket. Replace gasket if gauge is removed.

Do not reuse gasket. When reinstalling gauge head align head for proper orientation of the float inside tank. Torque head or

mounting screws evenly in several steps based on mounting screw size, gasket material & gauge head size & style.

CAUTION:

Improper gauge selection or application may result in in ac cu rate gauge readings.  Release of tank

contents as well as damage to equipment and safety hazard may result if tank is overfilled.  Fuel exhaustion may

occur if tank contents are less than indicated. This gauge is not a substitute for a fixed liquid level gauge or weight

measurement device that may be required for filling.

WARNING: 

IMPROPER APPLICATION, INSTALLATION, OR USE OF THIS GAUGE MAY CAUSE SERIOUS INJURY OR

PROPERTY DAMAGE.

Reviews: