PROBLEM
CAUSE
SOLUTION
5. Venting smoke and / or
gases from the front, bad
smell
First lighting
Flammable or combustible items in the enclosure or
surrounding walls of the equipment
Crack in the combustion chamber of the equipment
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
6. Excessive draft
Incorrect duct
Combustion control registers in the wrong position
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
The CE label is located on the appliance.
This label contains technical data and
OF number.
(This number can also be found in the guarantee).
THIS NUMBER IS ESSENTIALFOR ORDERING SPARE PARTS.
9. CE INFORMATION
WARNING:
-
All tests are carried out in observance of Regulationsm UNE-EN 13229:2002 - UNE-EN 13229:2002/A2:2005 - UNE-
EN 13229:2002/AC:2006– UNE-EN 3229:2002/A2:2005/AC:2007 - UNE-EN 60335
-
The review of the equipment, the installation and ducts
must be carried out by a professional.
-
In case of doubt regarding the described herein, please contact your Rocal dealer.
-
FAILURE TO COMPLY WITH THE OBLIGATIONS DESCRIBED HEREIN OR IMPROPER HANDLING OF THE
EQUIPMENT SHALL
EXONERATE THE MANUFACTURER OF ANY LIABILITY.
Summary of Contents for ARc 73 TC +Plus 180
Page 35: ...2 II 1 2 3 4 5 8 6 7 11 ...
Page 36: ...3 III 1 2 ...
Page 37: ...4 III 1 2 3 4 A B ...
Page 38: ...5 III C A 1 A 2 A 3 A 4 A 5 ...
Page 39: ...6 III A 6 A 7 A 8 A 9 B 1 B 2 ...
Page 40: ...7 III B 3 B 4 B 5 B 6 B 7 C 1 ...
Page 41: ...8 III C 2 C 3 C 4 ...
Page 42: ...9 IV D 1 D 2 D 3 D 4 D 5 D 6 ...
Page 43: ...10 IV D 7 D 8 D 9 D 10 D 11 D 12 ...
Page 44: ...11 IV D 13 D 14 D 15 D 16 D 17 D 18 ...
Page 45: ...12 IV D 19 D 20 D 21 D 22 D 23 D 24 ...
Page 46: ...13 IV D 25 ...