Operation Type
CW / CCW
Operation Type
CW / CCW
Wheel Mode
both are 0
Joint Mode
neither are 0
Multi-turn Mode both are 4095
The wheel mode can be used to wheel-type operation robots since motors of the robots spin
infinitely. The joint mode can be used to multi-joints robot since the robots can be controlled
with specific angles. Multi-turn mode allows joint mode control over multiple rotations (Position
range : -28,672 ~ 28,672)
2. 4. 7. Temperature Limit (11)
Unit
Value Range
About 1°C
0 ~ 100
CAUTION
: Do not set the temperature higher than the default value. When the temperature alarm
shutdown occurs, wait 20 minutes to cool the temperature before re-use. Keep using the product when
the temperature is high can cause severe damage.
2. 4. 8. Min/Max Voltage Limit (12, 13)
It is the operation range of voltage.
Unit
Value Range Description
About 0.1V
50 ~ 160
5.0 ~ 16.0V
For example, if the value is 80, the voltage is 8V. If
Voltage Range Error Bit (Bit0) of Status Packet is returned as ‘1’ and Alarm is triggered as set
in the addresses 17 and 18.
It is the torque value of maximum output. 0 to 1,023 (0x3FF) can be used, and the unit is about
0.1%.
For example, Data 1,023 (0x3FF) means that DYNAMIXEL will use 100% of the maximum
torque it can produce while Data 512 (0x200) means that DYNAMIXEL will use 50% of the
maximum torque.
When the power is turned on,
uses the value as the initial value.
2. 4. 10. Status Return Level (16)
This value decides how to return Status Packet when DYNAMIXEL receives an Instruction
Packet.
Value Responding Instructions
Description
0
PING Instruction
Status Packet will not be returned for all Instructions