![Robotis MX-106R Manual Download Page 6](http://html.mh-extra.com/html/robotis/mx-106r/mx-106r_manual_1471425006.webp)
Address
Size
(Byte)
Data Name
Description
Access
Initial
Value
30
2
Desired Position
RW
-
32
2
Moving Speed(Moving Velocity)
RW
-
34
2
Torque Limit(Goal Torque)
RW
ADD 14&15
36
2
Present Position
R
-
38
2
Present Speed
R
-
40
2
Present Load
R
-
42
1
Present Voltage
R
-
43
1
Present Temperature
R
-
44
1
Registered
If Instruction is registered
R
0
46
1
Movement Status
R
0
47
1
Locking EEPROM
RW
0
48
2
Minimum Current Threshold
RW
0
50
2
Count Time in millisecond
R
0
68
2
Consuming Current
RW
0
70
1
Torque Control Mode On/Off
RW
0
71
2
Goal Torque
RW
0
73
1
Goal Acceleration
RW
0
2. 4. Control Table Description
2. 4. 1. Model Number (0)
This address stores model number of DYNAMIXEL.
2. 4. 2. Firmware Version (2)
This address stores firmware version of DYNAMIXEL.
2. 4. 3. ID (3)
The ID is a unique value in the network to identify each DYNAMIXEL with an Instruction
Packet. 0~252 (0xFC) values can be used as an ID, and 254(0xFE) is occupied as a broadcast
ID. The Broadcast ID(254, 0xFE) can send an Instruction Packet to all connected DYNAMIXEL
simultaneously.
NOTE
: Please avoid using an identical ID for multiple DYNAMIXEL. You may face communication
failure or may not be able to detect DYNAMIXEL with an identical ID.
2. 4. 4. Baud Rate (4)