background image

Cooling table

CKPMX-03M2

230 V 50-60 Hz

User manual

Read this manual before use and keep for future reference!

PDF version of this manual is available on www.robolabs.pro

Summary of Contents for CKPMX-03M2

Page 1: ...Cooling table CKPMX 03M2 230 V 50 60 Hz User manual Read this manual before use and keep for future reference PDF version of this manual is available on www robolabs pro ...

Page 2: ...ter during cleaning can cause short circuit and elec tric shock DO NOT USE excessive water or water jet for cleaning DO NOT SPILL water on electric panels or parts ALWAYS unplug equipment before cleaning or servicing No user serviceable parts inside DO NOT OPEN electric panel unless you are qualified for this WARNING Improper installation adjustment alteration service or maintenance can cause prop...

Page 3: ... and ventilation requirements 6 2 Intended use 7 2 1 Design and principle of operation 7 2 2 Operating order 7 3 Maintenance and cleaning 8 3 1 Daily cleaning 8 3 2 Conservation 8 4 Transportation and storage 9 5 Quality control check 9 6 Warranty obligations 10 7 Manufacturer details 10 A Wiring diagram 11 B Parts list 12 2 ...

Page 4: ...6 fasteners 1x Cable protective shroud w M5 fasteners 1x Perforated tray 1x Perforated tray with cutouts 1x Base frame with legs 1x Crumb tray baffler 3x Popcorn chute baffler 3x Popcorn chute w M5 fasteners 1x User manual 1 3 Assembling 1 Unpack the package carefully and check the delivery set 2 Remove protective film from all surfaces 3 Wipe all surfaces with a clean soft cloth dampen with dish ...

Page 5: ...4 1 Figure 2 Cable shroud 7 Put perforated trays 1 and 3 on the supports 4 using handles 2 see Fig 3 Note three cutouts shown by arrows on one tray that must match popcorn chutes CAUTION The perforated trays are heavy 21 kg each At least two persons required to handle them 1 4 3 2 Figure 3 Perforated trays 4 ...

Page 6: ... Fig 5 1 2 Figure 4 Popcorn chute Figure 5 Popcorn chute baffler 10 Insert crumb tray baffler see Fig 6 Figure 6 Crumb tray baffler 11 Plug the table in the wall outlet see Power requirements section 12 Turn the blower on see Fig 8 and ensure that air blows upwards from the perforated trays Turn the blower off 5 ...

Page 7: ...se frame marked with IEC 5021 sign The table comes with power cord fitted with Schuko plug CEE 7 4 Use relevant outlet 1 5 Ambient and ventilation requirements This equipment is designed to be operated at the ambient temperature from 5 C to 40 C 41 F to 104 F and relative humidity not more than 45 at 40 C 104 F while using at altitudes not exceeding 1000 m over the sea level The temperature decrea...

Page 8: ...After popcorn is cooled down operator opens the popcorn chutes 3 by removing popcorn chute bafflers and then discharge ready to eat product 1 2 5 3 4 Figure 7 Principle of operation 2 2 Operating order 1 Figure 8 ON OFF switch 1 Prepare caramel coated popcorn on SugarLips 100 machine 2 Once caramel coated popcorn is ready to be cooled and separated set ON OFF switch 1 see Fig 8 to ON position I 3 ...

Page 9: ...lug for any damages cuts and so on Damaged cord must be replaced before further use of the equipment 2 Remove popcorn chute bafflers and crumb tray baffler Rinse with warm water Wipe dry 3 Remove perforated trays Clean with a sponge or soft nylon bristle use dish soap or other suitable detergent if necessary Remove soap residues Wipe dry 4 Clean the crumb tray with a sponge or soft nylon bristle u...

Page 10: ...ient temperature during the transportation and storage must be between minus 25 C and 55 C 5 Quality control check Cooling table CKPMX 03M2 Product name model Serial no The equipment is made with accordance to mandatory requirements of the state standards actual technical documentation and approved for use QC Engineer STAMP HERE Signature Full name DD MM YYYY 9 ...

Page 11: ...hanged by manufacturer at any time due to improvements and or other reasons Technical specifications stated in this document are intended to act as a reference point which is neces sary to evaluate suitability of the equipment for the customer s needs and are not the subject of warranty policy The information stated in this document has been thoroughly checked and considered as ac curate one never...

Page 12: ...A Wiring diagram 450V 30uF H07RN F 3G1 5 H07RN F 3G1 5 SA 1 2 3 4 C XP N L PE Z1 Z2 U1 U2 M 11 ...

Page 13: ...rated tray 1 30618 3 Perforated tray with cutouts 1 30619 4 Product chute baffler 3 30617 5 Adjustable leg 4 21397 6 SA Rocker switch 1 17110 10 9 8 7 Pos WD sign Item QTY Part no 7 Nut M6 DIN 934 8 30627 8 Spring washer M6 DIN 127 8 25293 9 Flat washer M6 DIN 125 8 26059 10 Bolt M6x16 DIN 933 8 25290 12 ...

Page 14: ...e shroud 1 30623 12 Flat washer M5 DIN 125 3 30626 13 Spring washer M5 DIN 127 3 30625 14 Nut M5 DIN 934 3 30624 15 Popcorn chute 3 30620 16 Button head screw M5x12 12 22018 17 Pos WD sign Item QTY Part no 17 Crumb tray baffler 1 30616 XP Power cord with Schuko plug not shown 1 30631 13 ...