Switch 4
is used to programme which of the zone
input ports are to be wired
N/O
and which are to
be wired
N/C
.
These
ports will trigger when this
state is altered. Connect all the devices and make
sure they are in their normal state (alternatively
short comm. with the zones that are
N/C
and leave
the zones that are
N/O
disconnected).
Turn
Switch 4 on and off
to programme. The
programme LED will flash the number of times on
the chart below to confirm the desired zone input
configuration.
Zone:
1
2
3
4
1 flash
N/C
N/C
N/C
N/C
2 ”
N/O
N/C
N/C
N/C
3 ”
N/C
N/O
N/C
N/C
4 ”
N/O
N/O
N/C
N/C
5 ”
N/C
N/C
N/O
N/C
6 ”
N/O
N/C
N/O
N/C
7 ”
N/C
N/O
N/O
N/C
8 ”
N/O
N/O
N/O
N/C
9 ”
N/C
N/C
N/C
N/O
10 ”
N/O
N/C
N/C
N/O
11 ”
N/C
N/O
N/C
N/O
12 ”
N/O
N/O
N/C
N/O
13 ”
N/C
N/C
N/O
N/O
14 ”
N/O
N/C
N/O
N/O
15 ”
N/C
N/O
N/O
N/O
16 ”
N/O
N/O
N/O
N/O