10
4 OPERATION
GB
Control board
Key
:
On / Off
Switches the extractor motor on and off at the latest selected speed.
Indicates the selected speed.
Key
:
Speed control
Decreases the suction speed.
Key
:
Speed control
Increases the suction speed.
Key
:
Intensive speed
By pressing this key it is possible to activate the intensive speed from any previously se-lected speed.
The intensive speed can be acti-vated even when the motor is OFF. This speed has been timed at 10
minutes. After that time the system activates automatically the latest selected speed. This function is
suitable for cooking conditions when vapours and smells are of the utmost emission.
HI
appears. The spot down on the right side flashes once a second.
Key
:
Air Renewing
By pressing this key it is possible to set up the motor to a suction speed at 100 m3/h lasting 10 minu
-
tes every hour. After this the motor switches off automatically.
Indicates the
24
-function. The spot down on the right side flashes and the motor is on.
When the filter saturation is going on it is pos-sible to reset the alarm by pressing this key
for about 3 seconds. The indication is visible only when the motor is off.
Once the process is finished the previous indi-cation disappears:
FF
Indicates that the metal grease filters saturation alarm has been triggered, and the filters
need to be washed. The alarm is triggered after 100 working hours.
EF
Indicates that the charcoal filter satura-tion alarm has been triggered, and the fil-ter has
to be replaced; the metal grease filters must also be washed. The charcoal filter is triggered after 200
working hours.
Key
:
Stop delay 30 minutes
By pressing this key it is possible to set the delayed shutdown of the appliance to 30 min-utes. This
function is suitable for a complete elimination of the residual smells. It can be activated at any position,
and it is deactivated by pressing the key again or by switching off the motor.
Indicates alternately the selected speed of the hood and the time left before the hood shut-
down. The spot down on the right side flashes.
Key
:
Lighting
Turns light on and off .
Key
:
Lighting
Turns the second light unit on and off (ambient lighting).
Summary of Contents for VIZIO FX MURALE
Page 39: ...R 5 7 Composants Components Bauelemente Componenti Componentes Onderdelen 2 8 4 6 9 3 ...
Page 40: ...38 400 170 113 6 260 40 293 670 200 DESSOUS HOTTE PLAN TRAVAIL 410 1100 ...
Page 42: ...40 2 2 1 84 670 293 40 ...
Page 43: ...41 3 4 10 10 30 1070 260 4 A ...
Page 44: ...42 5 6 6 R 7a 7b ...
Page 46: ...44 400 DESSOUS HOTTE PLAN TRAVAIL 6 301 5 397 251 5 340 97 184 41 5 ...
Page 47: ...45 VIZIO FX 900 SMC 285 175 88 42 359 4 0 438 898 470 472 2 467 4 5 400 ...
Page 48: ...46 VIZIO FX 1100 SMC 438 285 175 42 88 359 4 0 472 1098 470 467 2 4 5 400 ...
Page 49: ...47 7 397 400 301 5 251 5 ...
Page 50: ...48 8 4 10 10 301 5 25 41 5 ...
Page 53: ...51 Beleuchtung Lighting Eclairage Luci Luz Verlichting Fig 9 Fig 10 1 2 1 1 2 2 ...
Page 54: ......
Page 55: ......