1      ELECTRICAL

• This cooker hood is fitted with a 3-core mains cable with a standard 10/16A earthed plug.

• Alternatively the hood can be connected to the mains supply via a double-pole switch having 3mm

minimum contact gap on each pole.

• Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on

the rating plate inside the cooker hood.

• Technical Specification: Voltage 220-240, single phase ~50/60Hz.

2      INSTALLATION ADVICE

• Ensure the cooker hood is fitted in compliance with the recommended fixing heights.

• To ensure the safe operation of this cooker hood, we recommend that the hood should not be fitted

below 65cm (for electric) or (70cm for gas) the measurements taken from the surface of the cooking

appliance to the underside of the cooker hood.

• It is a possible fire risk if the hood is not sited as recommended.

• To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles

on the underside of the cooker hood and the cooker hood should be positioned away from doors and

windows, which will create turbulence.

• Ducting

• If the room where the hood is to be used contains a fuel-burning appliance such as a central heating

boiler then its flue must be of the room sealed or balanced flue type.

• If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the

room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement

equivalent to the diameter of the ducting being fitted, if not larger.

• The ducting system for this cooker hood must not be connected to any existing ventilation system,

which is being used for any other purposes or to a mechanically controlled ventilation ducting.

• The ducting used must be made from fire retardant materials and the correct diameter must be used,

as incorrect sized ducting will affect the performance of this cooker hood.

• When the cooker hood is used in conjunction with other appliances supplied with energy other than

electricity, the negative pressure in the room must not exceed 0.04 mbar to prevent the fumes from

combustion being drawn back into the room.

• The appliance is for domestic use only and should not be operated by children or people who are

infirm without supervision.

• This appliance must be positioned so that the wall socket is accessible.

• This appliance is not intended for use by persons (including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

3      FITTING

Any permanent electrical installation must comply with the latest regulations concerning this type of

installation and a qualified electrician must carry out the work. Non-compliance could cause serious

accidents or injury and would deem the manufacturers guarantee null and void.

IMPORTANT - 

The wires in this mains lead are coloured in accordance with the following code :

                - green / yellow : earth                     - blue : neutral                          - brown : live

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured

Summary of Contents for Escale 2 centrale 900

Page 1: ...NL Instructions for use and installation Cooker Hood Istruzioni per l uso e l installazione Cappa Instrucciones de instalacion e utilizacion Campana Bedienungsanleitung und Einrichtung Dunstabzugshaub...

Page 2: ...TALACION DEL APARATO FUNCIONAMIENTO CONSEJOS DE UTILIZACION MANTENIMIENTO GARANTIA Y ASSISTENCIA TECNICA NOTA GB CONTENTS ELECTRICAL WIRING INSTALLATION ADVICE FITTING THE APPLIANCE OPERATION USEFUL H...

Page 3: ...cas tre raccord e un conduit de ventilation m canique contr l e V M C Lorsqu on vacue l air vici dans un conduit d vacuation veiller ce que celui ci ne soit pas d j exploit v hiculer des gaz ou fum es...

Page 4: ...e clapet anti retour C sur la sortie de l appareil Rep 6 et raccorder le tuyau flexible l vacuation ext rieure et la sortie de l appareil Fixer l ensemble l aide de colliers ou de ruban adh sif approp...

Page 5: ...s qu moteur teint Affiche 24 et le point en bas droite cli gnote tandis que le moteur est en service Une fois la proc dure termin e la signalisa tion visualis e en pr c dence s teint FF signale la n c...

Page 6: ...rver les prescriptions r glementaires locales concernant l vacuation de l air vici clairage Avant toute intervention sur l appareil mettre l interrupteur d allumage des lampes en position teinte Ne pa...

Page 7: ...riques et lectroniques Veuillez agir selon les r gles locales et ne pas jeter vos produits usag s avec les d chets domestiques usuels Jeter correctement votre produit usag aidera pr venir les cons que...

Page 8: ...are fitted ensure that there is an adequate supply of fresh air to the room Ensure the kitchen is fitted with an airbrick which should have a cross sectional measurement equivalent to the diameter of...

Page 9: ...g holes for 10 mm nuts and bolts Drill the different holes with the appropriate masonry bit When fixing the cooker hood to a plasterboard ceiling ensure it is reinforced as illustrated in Fig 3 and at...

Page 10: ...ot R onto the chimney bracket using the same fixing screws Fig 6a b Connect the ducting 150mm 6 INS not provided between motors item 6 and the recirculation spigot and secure the connections with appr...

Page 11: ...ions are only visible when the motor is turned off Displays 24 and the bottom right hand spot flashes while the motor is turned on On completing the procedure the previous indicator is turned off FF i...

Page 12: ...th or more frequently if the hood is used for more than 3 hours per day To remove and replace the metal grease filters Remove the metal grease filters one at a time by releasing the catches on the fil...

Page 13: ...on improper use or neglect the replacement of any light bulbs or filters or removable parts of glass or plastic These items are considered to be consumable under the terms of this guarantee 8 REMARKS...

Page 14: ...A1 1000 700 38 mini maxi 979 779 450 164 65 56 22 311 220 210 250 350 350 329 150 35 440 mini 650...

Page 15: ...Connection Unit to BS 1363 Part 4 fitted with a 3 Amp fuse is a recommendedmains supply connectionaccessoryto ensure compliance with the Safety Requirements applicable to fixed wiring instructions The...

Page 16: ...HITE PINK BLANC ROSE WEISS ROSA Y YELLOW JAUNE GELB 110914 PRESTIGE Centrale 1000 depuis Septembre 2011 From 3S_Prestige_C_100_V2011 09 Red White Brown Blue M N L1 F Blue Brown M 230 W L2 L2 e l p r u...

Page 17: ...A4 5 6 Composants Components Bauelemente Componenti Componentes Onderdelen R 7 8...

Page 18: ...A5 Colis Hotte Hood Parcel 1 2 4 3...

Page 19: ...A6 2a 7a 1 3 4 5 2b 220 210 50 50 50 50 50...

Page 20: ...A7 6a 6b 6c 7a...

Page 21: ...A8 7b 6c 2 1 2 3 2 2 1 3 2...

Page 22: ...A9 A 6d C 6 7...

Page 23: ...A10 8 9 7b 2 1 2 3 2 2 1 3 2...

Page 24: ...A11 10 11...

Page 25: ...A12 13MC092 323 x 262 x 9 mm 12 2 LR03 AAA 1 5V 1 3 ACCESSOIRES ACCESSORI ACCESSORIES ACCESORIA ZUBEH RE ACCESSOIRES GU10 28 W 230 V Code 12EC024...

Page 26: ...A13 Halogen Beleuchtung Halogen Lighting Eclairage halog ne Alogene Luci Al genas Luz Halogeen Verlichting 4 x 20 W 12 V 1 2...

Page 27: ...A14 GU10 28 W 230 V Code 12EC024 3 4...

Page 28: ...rie Numero de serie Serienummer Mod le Model Modell Modello Modelo Model Plaque Signal tique de la hotte Rating plate of the cookerhood Typenschild im Inneren der Dunstesse Etichetta all interno della...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...25 Rue des Rosiers Sainte C cile B P 60056 50800 VILLEDIEU LES PO LES France T l 02 33 91 26 50 Fax 02 33 51 54 79 e mail com france roblin fr For outside France Tel 33 0 2 33 91 26 57 Fax 33 0 2 33 5...

Reviews: