14
GB
INSTALLATION
Wall drilling and bracket fixing
Wall marking:
• Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre
of the area in which the hood will be installed.
• Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at
height H (H = height of the visible part of the panel) for installation with the back panel.
• Place bracket 7.1 on the wall as shown, 287 mm above the horizontal reference line, aligning the
centre (notch) with the vertical reference line.
• Mark the wall at the centres of the holes in the bracket.
• Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning
the centre (notch) with the vertical reference line.
• Mark the wall at the centres of the holes in the bracket.
• Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper
chimney section supplied), aligning the centre (notch) with the vertical line.
• Mark the wall at the centres of the holes in the bracket.
REAR PANEL (OPTIONAL)
The Rear Panel must be fitted before fixing the hood body and, for both upper an lower positiion
fixing, must be fitted at the correct height prior to installing the bases. As this operation is rather
complex, it should be carried out either by the kitchen installer or a qualified person who knows the
final dimensions of the units.
For the upper fixing position, proceed as follows:
• Rest the back panel on the base, inserting the lower plate between the upper surface and the wall,
centring it on the vertical reference line.
• Mark the centres of the two holes in the upper plate.
H 287
X
1÷2
650 min.
7.2.1
7.1