DESCRIPTION
The Bantam Ecotherm is a room sealed gas wall heater which circulates warm air by convection. It is manually
ignited by a combined piezo igniter and gas tap which has OFF, PILOT and ON positions. The setting of the
thermostat and the room temperature determine if the main burner lights when the gas tap is turned to ON, after
lighting the pilot. A thermoelectric F.F.D. is fitted. Three different lengths of flue are available to enable the heater to
be fitted on walls from 75mm (3in) to 50Omm (20in) thick. The flues have eccentric ducts made from aluminium
coated steel sheet and a one piece terminal made from weather resistant aluminium. The heat exchanger is
assembled from pressings made from either aluminium coated or heat resistant sheet steel. The main burner is an
aerated ribbon type and the pilot burner is a target type. The case is made from stoved painted mild steel.
Height:
582mm x Width: 316mm x Depth: 18Omm
Weight:
14.2kg Gross: 12kg Nett
Gas inlet:
Rc1/4 (1/4 in BSP internal).
Gas supply:
Natural gas (G20) at 20mbar
Burner pressure (hot):
19.0+/-1mbar
INPUT(gross): 2.94kW
OUTPUT
2.11 kW
Main injector:Robinson Willey N16
Pilot Injector:
S.I.T. No.34
Pilot rate is non adjustable.
The spark gap: 3-4mm. The gap is set by design and is not adjustable.
Burner aeration: Non adjustable. Flame should be blue.
Flues:
Short for walls 75mm (3in) to 195mm (7.7in)
Part No. 991429
Standard for walls 195mm (7.7in) to 345mm (13.6in)
Part No. 991428
Long for walls 345mm (1 3.6in) to 50Omm (20in)
Part No. 991427
Optional extras:
Kit for combustible walls:
Part No. 994530
Flue Terminal guard:
Part No. 998793
Arthritic Handle:
Part No. 997259
316mm
105mm
inlet connection
35mm
130mm
180mm
134mm
127mm
582mm
FIG 1
442mm
finished floor level
SPECIFICATION
Declaration of Efficiency
The efficiency of this appliance has been measured as specified in BS EN 613:2001 and the
result is 78.7%. The gross calorific value of the fuel has been used for this efficiency
calculation. The test data from which it has been calculated has been certified by Notified
Body No.0087. The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
The above exceeds the minimum requirement of 72%.