DESCRIPTION
The Bantam Ecotherm is a room sealed gas wall heater which circulates warm air by convection. It is manually 
ignited by a combined piezo igniter and gas tap which has OFF, PILOT and ON positions. The setting of the 
thermostat and the room temperature determine if the main burner lights when the gas tap is turned to ON, after 
lighting the pilot. A thermoelectric F.F.D. is fitted. Three different lengths of flue are available to enable the heater to 
be fitted on walls from 75mm (3in) to 50Omm (20in) thick. The flues have eccentric ducts made from aluminium 
coated steel sheet and a one piece terminal made from weather resistant aluminium. The heat exchanger is 
assembled from pressings made from either aluminium coated or heat resistant sheet steel. The main burner is an 
aerated ribbon type and the pilot burner is a target type. The case is made from stoved painted mild steel.

Height:

582mm x Width: 316mm x Depth: 18Omm

Weight:

14.2kg Gross: 12kg Nett

Gas inlet:

Rc1/4 (1/4 in BSP internal).

Gas supply:

Natural gas (G20) at 20mbar

Burner pressure (hot):

19.0+/-1mbar

INPUT(gross): 2.94kW

OUTPUT

2.11 kW

Main injector:Robinson Willey N16
Pilot Injector:

S.I.T. No.34

Pilot rate is non adjustable.
The spark gap: 3-4mm. The gap is set by design and is not adjustable.
Burner aeration: Non adjustable. Flame should be blue.
Flues:

Short for walls 75mm (3in) to 195mm (7.7in)

Part No. 991429

Standard for walls 195mm (7.7in) to 345mm (13.6in)

Part No. 991428

Long for walls 345mm (1 3.6in) to 50Omm (20in)

Part No. 991427

Optional extras:
Kit for combustible walls:

Part No. 994530

Flue Terminal guard:

Part No. 998793

Arthritic Handle:

Part No. 997259

316mm

105mm

inlet connection

35mm

130mm

180mm

134mm

127mm

582mm

FIG 1

442mm

finished floor level

SPECIFICATION

Declaration of Efficiency

The efficiency of this appliance has been measured as specified in BS EN 613:2001 and the 
result  is  78.7%.  The  gross  calorific  value  of  the  fuel  has  been  used  for  this  efficiency 
calculation. The test data from which it has been calculated has been certified by Notified 
Body  No.0087.  The  efficiency  value  may  be  used  in  the  UK  Government's  Standard 
Assessment Procedure (SAP) for energy rating of dwellings.

The above exceeds the minimum requirement of 72%.

Summary of Contents for Bantam Ecotherm

Page 1: ...features a wide range of information which may be of use to you and is available 24 hours a day It includes Manuals and guides downloads Servicing Where to buy our products Literature downloads www r...

Page 2: ...Bantam Ecotherm Instructions for Installation and Servicing This is a Cat I appliance for use on G20 20mbar in GB IE Please leave these instructions with the User 2H 988939 Issue 8...

Page 3: ...Gas supply Natural gas G20 at 20mbar Burner pressure hot 19 0 1mbar INPUT gross 2 94kW OUTPUT 2 11 kW Main injector Robinson Willey N16 Pilot Injector S I T No 34 Pilot rate is non adjustable The spar...

Page 4: ...ssembly complete with sealing tape 2 Gasket pack comprising flue and air duct gaskets and flue sealing gasket 3 Flue sealing ring 4 Flue cover plate See Fig 2 for items 1 to 4 5 Thermostat and Control...

Page 5: ...he top of the heater must not be less than15Omm 6in The shelf must not project more than 15Omm 6in from the wall 5 Check the wall thicknesses Three different sizes of flue are available for wall thick...

Page 6: ...e template 3 Cut a hole 135mrn dia for the air inlet duct making sure that it is straight and level making good the wall at both ends if necessary 4 Drill the three fixing holes to a minimum depth of...

Page 7: ...section of the wall Cut the wall liner to this length cutting at the end without the fixing brackets Fit the liner to the sealing plate using the screws provided Fit the assembly to the inside face of...

Page 8: ...marked TOP Set the overall length of the flue to the dimension A Fig 6 Drill 2 7mm diameter for the fixing screws but do not fit them yet Remove the flue terminal 4 Slide the sealing ring sealing gas...

Page 9: ...nel Lower the bottom of the case and fasten it with the retaining screws Refit the dressing strip flanged edge to front and replace the control and thermostat knobs 8 Check that the heater lights inst...

Page 10: ...ermostat do not fully tighten 7 Feed the assembly back into the heater taking care to engage the injector housing complete with it s sealing gasket and the supply tube into the gas control Re fit the...

Page 11: ...tight 6 PILOT ELECTRODE 1 Release the tubing nut and remove the thermocouple from the pilot assembly 2 Disconnect the electrode lead unscrew the tubing nut and remove the electrode 3 Replace the elec...

Page 12: ...ove three screws securing the frame to heat exchanger Take off the frame gaskets and Broken glass 2 Refit new window kit if required 10 CASE The perforated panel and control panel can be replaced by r...

Page 13: ...ing screw 1 999542 51 203910 Injector RW N16 1 997629 42 391699 Pilot Injector 1 820238 26 203749 Coverplate gasket 1 999053 34b Thermostat Knob 1 988943 Brown model 34c Thermostat Knob 1 988942 Paste...

Reviews: