background image

 

        

 

 

 
 

Contact

 

Details

 

 

Please

 

note

 

that

 

some

 

of

 

the

 

contact

 

details

 

on

 

this

 

PDF

 

document

 

may

 

not

 

be

 

current.

 

 

Please

 

use

 

the

 

following

 

details

 

if

 

you

 

need

 

to

 

contact

 

us:

 

 

Telephone:

 

0844

 

879

 

3588

 

Email:

 

[email protected]

 

 
 

The

 

Help

 

Centre

 

section

 

of

 

this

 

website

 

also

 

features

 

a

 

wide

 

range

 

of

 

information

 

which

 

may

 

be

 

of

 

use

 

to

 

you

 

and

 

is

 

available

 

24

 

hours

 

a

 

day.

 

It

 

includes:

 

 

 

Manuals

 

and

 

guides

 

downloads

 

 

Servicing

 

 

Where

 

to

 

buy

 

our

 

products

 

 

Literature

 

downloads

 

 

www.robinsonwilley.co.uk/help

 

A division of GDC Group Ltd 
Millbrook House   Grange Drive   Hedge End   Southampton   SO30 2DF 
www.robinsonwilley.co.uk

 

Registered No: 1313016 England

VAT GB 287 1315 50004 

EEE Producer Registration Number – 

WEE/GE0057TS 

Paper from sustainable sources 

Summary of Contents for Bantam Ecotherm

Page 1: ...features a wide range of information which may be of use to you and is available 24 hours a day It includes Manuals and guides downloads Servicing Where to buy our products Literature downloads www r...

Page 2: ...Bantam Ecotherm Instructions for Installation and Servicing This is a Cat I appliance for use on G20 20mbar in GB IE Please leave these instructions with the User 2H 988939 Issue 8...

Page 3: ...Gas supply Natural gas G20 at 20mbar Burner pressure hot 19 0 1mbar INPUT gross 2 94kW OUTPUT 2 11 kW Main injector Robinson Willey N16 Pilot Injector S I T No 34 Pilot rate is non adjustable The spar...

Page 4: ...ssembly complete with sealing tape 2 Gasket pack comprising flue and air duct gaskets and flue sealing gasket 3 Flue sealing ring 4 Flue cover plate See Fig 2 for items 1 to 4 5 Thermostat and Control...

Page 5: ...he top of the heater must not be less than15Omm 6in The shelf must not project more than 15Omm 6in from the wall 5 Check the wall thicknesses Three different sizes of flue are available for wall thick...

Page 6: ...e template 3 Cut a hole 135mrn dia for the air inlet duct making sure that it is straight and level making good the wall at both ends if necessary 4 Drill the three fixing holes to a minimum depth of...

Page 7: ...section of the wall Cut the wall liner to this length cutting at the end without the fixing brackets Fit the liner to the sealing plate using the screws provided Fit the assembly to the inside face of...

Page 8: ...marked TOP Set the overall length of the flue to the dimension A Fig 6 Drill 2 7mm diameter for the fixing screws but do not fit them yet Remove the flue terminal 4 Slide the sealing ring sealing gas...

Page 9: ...nel Lower the bottom of the case and fasten it with the retaining screws Refit the dressing strip flanged edge to front and replace the control and thermostat knobs 8 Check that the heater lights inst...

Page 10: ...ermostat do not fully tighten 7 Feed the assembly back into the heater taking care to engage the injector housing complete with it s sealing gasket and the supply tube into the gas control Re fit the...

Page 11: ...tight 6 PILOT ELECTRODE 1 Release the tubing nut and remove the thermocouple from the pilot assembly 2 Disconnect the electrode lead unscrew the tubing nut and remove the electrode 3 Replace the elec...

Page 12: ...ove three screws securing the frame to heat exchanger Take off the frame gaskets and Broken glass 2 Refit new window kit if required 10 CASE The perforated panel and control panel can be replaced by r...

Page 13: ...ing screw 1 999542 51 203910 Injector RW N16 1 997629 42 391699 Pilot Injector 1 820238 26 203749 Coverplate gasket 1 999053 34b Thermostat Knob 1 988943 Brown model 34c Thermostat Knob 1 988942 Paste...