Instructions for use and maintenance
Automatic pre-heating
This automatic device facilitates the cooking process because you do not need to
supervise the whole cooking cycle.
This function preheats the burner on maximum power in order to bring it rapidly
up to the required temperature. After a given time interval, the power level returns
spontaneously to the established setting.
Enabling automatic preheating
Select level 9 by means of the “
-
“ key, then select level 9 with the “
+
” key. Finally
select the required power setting, e.g. level 6, with the “
-
“ key.
In automatic preheating mode, the display for the burner concerned will alternately
show the actual setting (“
6
”) and the symbol “
A
”.
Example: Select level 9 to enable automatic preheating with the “
+
” key. Then bring
the level down to 6 using the “
-
“ key. In this way, the burner will be preheated on full
power for 9’00”, while the display alternately reads “A” and “6”. After 9’00” the
burner will return to the power level 6.
Changing the power level in the automatic preheating phase
•
The burner involved must be on.
•
Change the level by means of the “
+
” keys.
•
If the setting is raised, the new preheating time is recalculated taking the time
that has already elapsed for the previous setting into account.
Disabling the automatic preheating function
•
With the symbol “
A
” showing on the burner display:
•
The burner concerned must be on.
•
Touch the “
-
“ key (E) at least 10 seconds after enabling the function.
Pause function
When at least one of the cooking zone is activated, the heating element may be “paused” by pressing the Pause key
(C). All the displays show a symbol according picture and the corresponding pilot light (C
1
) is turned on.
In order to terminate the pause mode press again the Pause key (C) and one of the other keys.
Recall function
When the control had been switched off with the power key by mistake, the settings
may be recovered quickly by using the recall function (within a short time).
After switching on the power key, the “Pause/Recall” pilot light (C
1
) is blinking to
display that it is possible to recover the previous settings.
Press the “Pause/Recall” key (C). The setting would be recovered.
Level
Time limit (min/sec)
1
50’’
2
1’30’’
3
2’30’’
4
3’40’’
5
6’20’’
6
9’00’’
7
2’30’’
8
4’00’’