- 21 -
①
②
③
④
ⓐⓑ
AVR unit
①
②
③
④
ⓐ
ⓑ
Green
White
Blue
Blue
White
Red
(c) IDENTIFYING A .V .R . TROUBLE by
MOUNTING and OPERATING in THE
GENERATOR
SCR or transistor damage cannot be
detected by simply looking at the A .V .R . or
checking the lead resistance .
Check it by mounting the suspectedly faulty
A .V .R . in a normal generator, or mount a
mormal A .V .R . in a generator which fails to
generate voltage .
*.Checking.table.for.analogue.circuit.tester.
..RGX7100./.RGX7800
(Ω)
(R
±
20%)
Apply.black.
⊖
.needle.of.the.circuit.tester
White.
ⓐ
Red.
ⓑ
Green.
①
White.
②
Blue.
③
Blue.
④
Apply.red.
⊕
.needle.
of.the.circuit.tester
White.
ⓐ
-
2 .1M
5 .0M
5 .1M
4 .6M
4 .2M
Red.
ⓑ
1 .8M
-
2 .1M
2 .1M
1 .9M
1 .6M
Green.
①
4 .4M
2 .0M
-
4 .9M
4 .4M
4 .1M
White.
②
4 .6M
2 .1M
5 .1M
-
4 .6M
4 .2M
Blue.
③
4 .0M
1 .7M
4 .5M
4 .5M
-
3 .8M
Blue.
④
4 .2M
1 .8M
4 .7M
4 .7M
4 .2M
-