9. ELECTRIC STARTER
9-1 OPERATION AND FUNCTION
When key switch is turned ON, lower electric current (M
→
) flows through coil of magnetic switch and the
coil is excited. The plunger is pulled and higher current (S
→
) flows through electric starter.
When electric starter is operated, pinion gear is pushed out by means of centrifugal force of weight located
in the spline of armature shaft. The pinion gear is engaged with ring gear and flywheel and crankshaft are
rotated.
STARTING MOTOR
ELECTRIC STARTER
S
S
M
M
M
M
M
KEY SWITCH
MAGNETIC
SWITCH
BATTERY
Fig. 9-2
NOTE ;
For Electric starter operation, electric wiring should be connected among electric starter,
key switch and battery as shown in the diagram.
CARBURETOR
OIL
PRESSURE
SWITCH
IGNITION
COIL #1
STOP
DIODE
IGNITION
COIL #2
SPARK
PLUG
SPARK
PLUG
CHARGE
COIL
ELECTRIC
STARTER
REGURATOR
OIL WARNING LAMP
BATTERY
12V
TACHO / HOUR METER
(HIGH TENSION CORD)
RED
RED
RED
BLACK
BLACK
GREEN
GRAY
BLACK
BLACK
WHITE
YELLOW
YELLOW
BLACK / WHITE
S
B
M
G L
KEY
SWITCH
Key switch (Option parts)
G
M
B
L
S
OFF
Terminal
Key
Position
RUN
START
Fig. 9-1