Installation Location

RS9320T

Install the thermostat 4 to 5 feet above the floor in an area with good air 

circulation and average temperature.

For new installations, mount thermostat on an inside wall, 4-5 feet above the floor. 

Do not install the thermostat in the following locations:

• Behind a Door 
• In a Corner
• Near Air Vents
• In Direct Sunlight
• With an Outside Wall Behind the Thermostat
• Near any Heat or Steam Generating Fixtures
• Near any Concealed Pipes or Chimneys

Installation at these locations will affect thermostat operation.

Thermostat System Types

Table of Contents 

Page

Installation Location 

Mounting & Battery Installation

3

Thermostat Quick Reference 

Wiring 

Wiring Diagrams 

6-8 

Installer Setup Menu 

9-12 

Programming Notes 

13-15 

Thermostat Quick Reference

16

Power Type

Battery Power 

Hardwire (Common Wire) 

Gas, Oil, or Electric Heat with Air Conditioning 
Heat Pumps (without auxiliary or emergency heat) 
Multi-Stage Systems 
Heat-Only, including for Floor and Wall-Furnace 
Cool-Only 
750 Millivolt Heating Systems 

IMPORTANT SAFETY 

INFORMATION WARNING:
•  Always turn off power at the main 

power source by unscrewing fuse or 

switching circuit breaker to the off 

position before installing, removing, 

cleaning, or servicing thermostat. 

•  Read all of the information in 

this manual before installing or 

programming this thermostat. 

•  This is a 24V AC low voltage 

thermostat. Do not install on 

voltages higher than 30V AC. 

•  All wiring must conform to local 

and national building and electrical 

codes and ordinances.

•  Do not short (jumper) across 

terminals on the gas valve or at the 

system control to test installation. 

This will damage the thermostat 

and void the warranty.

Specifications

Temperature Display Range ................32°F to 99°F (0°C to 40°C)

Temperature Control Range ...............41°F to 90°F (5°C to 32°C)

Load Rating ................................................ 1 amp per terminal, 1.5 amp maximum all 

terminals combined

Differential .................................................. Heating is adjustable from 0.2° to 2.0° 

Cooling is adjustable from 0.2° to 2.0°

Power Source ............................................ 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire 

Battery power from 2 AAA Alkaline batteries

Operating Ambient Temperature .....32°F to +105°F (0°C to +41°C)

Operating Humidity ...............................90% non-condensing maximum
Dimensions ................................................4.7”W x 4.4”H x 1“D

Wallplate Installation

Horizontal Mount 

Vertical Mount

For a vertical mount, put screws 

on the top and bottom.

For a horizontal mount, put screws 

on the left and the right.

1

2

 

Caution:

Electrical Hazard

Disconnect power before installing this 

product. Failure to do so can cause electric 

shock or equipment damage.

 

Mercury Notice

This product is mercury-free. However, 

if this product is replacing a control 

which contains mercury, it needs to 

be disposed of properly. Contact your 

local waste management authority for 

instructions regarding recycling and 

proper disposal of the control.

1

2

Mounting & Battery Installation

Thermostat Quick Reference 

Mounting Thermostat

Battery Installation

Important:

Getting to know your thermostat 

Align the 4 tabs on the faceplate with the 

corresponding slots on the back of the 

thermostat, then push gently until the 

thermostat snaps into place.

High quality alkaline batteries are recommended. 

Rechargeable batteries or low quality batteries are not 

recommended.

Battery installation is optional if used with AC power 

(the C terminal is connected). During power outages, 

the batteries will save settings and power the display.

Insert 2 AAA 

Alkaline batteries 

(included). High 

quality alkaline 

batteries are 

recommended.

Fan Buttons
Next Step Buttons
Set Time Buttons 
Program Buttons
Menu Buttons 
System Buttons 
Set-Point Buttons 
Battery Cover
Button/Battery Access Door

Days of the week and time
Indicates the current room 

temperature
Displays the user selectable  

set-point temperature 
Hold is displayed when thermostat 

program is overridden. 
System Operation Indicators:  

The compressor delay is active if 

these are flashing. 
Programmable Time Periods: 

Residential uses 4 time periods - 

WAKE, RETURN, LEAVE and SLEEP
Program Menu Options: 

Shows different options during 

programming.
Low Battery Indicator: Replace 

batteries when this indicator is 

shown.

1

1
2

3

4

5

6

7

8

2
3

4
5

6

7

5
5

3

4

Heat

Menu

FAN

Set At

Sun

WAKE

Auto 

On 

IAQ

SYSTEM

Set At

Auto 

On 

IAQ

SYSTEM

FAN

Technician 

Setup 

Next Step

Set Time 

Clean 

Next Zone

Set Schedule 

Hold 

Previous Step

Run Schedule

 Menu 

Done

Heat ON 

Cool 

Auto 

Em.heat

HOLD

Sun Mon Tue Wed Thu Fri Sat

WAKE LEAVE RETURN SLEEP

Auto 

On 

IAQ

Set At

SYSTEM

FAN

Technician 

Setup 

Next Step

Set Time 

Clean 

Next Zone

Set Schedule 

Hold 

Previous Step

Run Schedule

 Menu 

Done

Heat Off 

Cool 

Auto 

Em.heat

HOLD

Sun Mon Tue Wed  Thu Fri Sat

WAKE LEAVE RETURN SLEEP