ROBERTS GORDON
®
T F-S
E RIE S
S
U BMI TT AL
S
HEE T
© 2004 Roberts-Gordon
APPLI CAT IONS, ENGIN EE RING AND DE TAI LE D GUIDANCE ON SYST EMS DE SI GN, I NSTALL ATION AND PRODUCT PE RFORMANCE I S AVAIL ABL E UPO N REQUE ST. ROBERTS GO RDON
®
PRODUCTS ARE TO BE
INSTAL LE D ONLY I N ACCOR DANCE WIT H L OCAL L AW S, CODES AND RE GULAT IONS, AND ONLY BY A CONTRACTO R QUALI FIE D IN THE INST AL LAT ION AND SE RVICE OF GAS-F IRE D HEAT ING E QUIPMEN T.
BBurner Tube Installation
Burner Installation
7' 6" ± 1'
(
22
9
cm
±
2
5
cm
)
S
H
ook
Burner
Tube
H
anger
2
9"±
2
"
(73
cm
± 5
cm
)
NOTE:
Tubing
re
q
uires
a
downward
slope
of
1/
2
" (13
mm
)
per
2
0' (6
m
)
away
from
burner.
W
eld
S
eam
must
be
to
the
bottom
of
the
tube.
O
ffset
mounting
hole
must
be
to
the
top
Description
Par t Number
Burner Tube
03051XXX
S-Hook
91907302
Tube/Ref lector Hanger
03090100
L
ock
W
asher
Gasket
Burner
Bolt
Description
Part Number
Bolt
94273914
Lock Washer
96411600
Gasket
02568200
Burner
090XXXXX