pg 33
Conduit Hole
Internal Wire Bundle
Green
White
Black
L1
Wire-nut the wires together
L2
Gnd.
Burner Box
Green to Gnd.
White to L2
Black to L1
Liquid Tight Flexible
Conduit for Outdoor Use
or Equivalent
Liquid Tight
Conduit Connector
Conduit Hole
Burner Box
Internal Wire Bundle
L1
L2
Gnd.
Wire-nut the wires together
GreenWhite Black
Blue
Purple
Blue to transformer
Purple to valve
From External Thermostat
Green to Gnd.
White to L2
Black to L1
Liquid Tight Flexible
Conduit for Outdoor Use
or Equivalent
Liquid Tight
Conduit Connector
Figure 31a. Electrical Connection to the Burner Box using Line Voltage Thermostat on Control
Figure 31b. Electrical Connection to the Burner Box with Optional External Low Voltage Thermostat
FOR EXTERNAL THERMOSTAT CONNECTION:
Run 2 wires from low voltage thermostat through conduit as shown. The purple wire from the valve and the blue wire from
the transformer have 1/4" (6 mm) blade female electrical terminals, which are connected by a black jumper wire. Cut the
female connections off the ends of the blue and purple wires and strip the ends approximately 1/2" (1.3 cm). Connect
these 2 wires to the thermostat wires using suitable wire connectors.
WARNING
ATTENTION
If any of the original wire as supplied with the heater
must be replaced, it must be replaced with wiring
material having a temperature rating of at least
105°C and 600 volts.
Si une partie du câblage dorigine fourni avec le
radiateur doit être remplacée, elle doit lêtre par du
matêriel de câblage tolérant une température dau
moins 105°C et 600 volts.