B
LACKHEAT
®
I
NSTALLATION
O
PERATION
AND
S
ERVICE
M
ANUAL
74 of 75
* Only a
v
ailable in M
u
ltib
u
rner.
NOTE: Factory recommended and minim
u
m installation heights are listed as a g
u
ideline. If infrared heaters are
mo
u
nted too lo
w
, they may res
u
lt in heat discomfort. It is generally ad
v
ised to obser
v
e the recommended mo
u
nting
heights to optimize comfort conditions.
Ho
w
e
v
er, certain applications s
u
ch as spot heating, freeze protection, o
u
tdoor patio heating or
v
ery high ceilings may
res
u
lt in the heaters being mo
u
nted o
u
tside of the factory recommended and minim
u
m mo
u
nting heights. Clearances
to comb
u
stibles m
u
st al
w
ays be maintained.
1
8
.7 Linear Heater
BH
15
ST
BH
20
ST
BH
25
ST
BH
25
ST
/EF
BH
30
ST
BH
30
ST
/EF
BH
35
ST
BH
35
ST
/EF
BH
40
ST
BH
40
ST
/EF
BH
45
ST
BH
45
ST
/EF
BH
50
ST
BH
50
ST
/EF
BH
55
ST
*
Inp
u
t - Gross (kW)
15
20
25
30
35
40
45
50/51
55
Inp
u
t - Net (kW)
13.5
18
22.5
27
31.5
36
40.5
45/46
49.5
T
u
be Length (mm)
6096
9144
9144
12192
12192
12192
15240
15240
18288
O
v
erall Heater Length (mm)
6661
9709
9709
12757
12767
12767
15815
15850
18579
Weight (kg)
39
55
55
68
68
68
81
81
95
Heated Area (m
2
)
20-160
30-210
40-265
50-315
55-370
65-420
70-475
80-525
90-620
Minim
u
m Installation
Height(mm)
3500
3500
3500
3500
4600
5000
5000
5000
6000
Recommended Installation
Height (mm)
3500
3600
3900
4200
4800
5500
6700
7600
8000
1
8
.
8
Double Linear Heater
BH
30
DL
BH
40
DL
BH
50
DL
BH50
DL
/EF
BH
60
DL
BH60
DL
/EF
BH
70
DL
BH70
DL
/EF
Inp
u
t - Gross (kW)
30
40
50
60
70
Inp
u
t - Net (kW)
27.5
36
45
54
63
T
u
be Length (mm)
12802
18898
18898
24994
24994
O
v
erall Heater Length (mm)
13462
19558
19558
25654
25654
Weight (kg)
82
110
110
136
136
Heated Area (m
2
)
50-315
65-420
80-525
100-630
110-740
Minim
u
m Installation Height (mm)
3500
3500
3500
3500
4600
Recommended Installation Height
(mm)
3500
3600
3900
4200
4800
1
8
.9 U-Tube Heater
BH
1
5
U
T
BH
2
0
U
T
BH
2
5
U
T
BH
2
5
U
T
/EF
BH
3
0
U
T
BH
3
0
U
T
/EF
BH
3
5
U
T
BH
3
5
U
T
/EF
BH
4
0
U
T
BH
4
0
U
T
/EF
BH
4
5
U
T
BH
4
5
U
T
/EF
BH
5
0
U
T
BH
5
0
U
T
/EF
Inp
u
t - Gross (kW)
15
20
25
30
35
40
45
50
Inp
u
t - Net (kW)
13.5
18
22.5
27
31.5
36
40.5
45
T
u
be Length (mm)
3531
5055
5055
6579
6579
6579
8103
8103
O
v
erall Heater Length (mm)
3822
5346
5346
6870
6870
6870
8394
8394
Weight (kg)
41
54
54
65
65
66
96
96
Heated Area (m
2
)
20-160
30-210
40-265
50-315
55-370
65-420
70-475
80-525
Minim
u
m Installation Height (mm)
3500
3500
4000
4700
5000
5000
5000
5000
Recommended Installation Height (
mm
)
3500
3600
4000
4700
5000
5500
6700
7600
Summary of Contents for Blackheat BH15ST
Page 2: ......
Page 4: ......
Page 6: ......
Page 33: ...SECTION 7 U TUBE HEATER INSTALLATION 27 of 75 Figure 23 U Tube Assembly Overview mm 200 ...
Page 63: ...SECTION 13 WIRING 57 of 75 13 4 Typical External Wiring Diagram Multiburner ...
Page 64: ...BLACKHEAT INSTALLATION OPERATION AND SERVICE MANUAL 58 of 75 13 5 Internal Wiring Diagram ...
Page 82: ......
Page 83: ......