SECTION 1: HEATER SAFETY
Your Safety is Important to Us!
This symbol is used throughout the manual
to notify you of possible fire, electrical or burn
hazards. Please pay special attention
w
hen
reading and follo
w
ing the
w
arnings in these
sections.
Installation, ser
v
ice and annual inspection of heater must
be done by a registered installer/contractor qualified in
the installation and ser
v
ice of gas-fired heating
equipment.
Read this manual carefully before installation, operation
or ser
v
ice of this equipment.
This heater is designed for heating nonresidential indoor
spaces. Do not install in residential spaces. These
instructions, the layout dra
w
ing, local codes and
ordinances, and applicable standards that apply to gas
piping, electrical
w
iring,
v
enting, etc. must be thoroughly
understood before proceeding
w
ith the installation.
Protecti
v
e gear is to be
w
orn during installation, operation
and ser
v
ice. Thin sheet metal parts, such as the reflector
portion of the heater and the
v
arious
v
enting
components, ha
v
e sharp edges. To pre
v
ent injury, the use
of
w
ork glo
v
es is recommended. The use of glo
v
es
w
ill
also pre
v
ent the transfer of body oils from the hands to
the surface of the reflector.
Before installation, check that the local distribution
conditions, nature of gas and pressure, and adjustment of
the appliance are compatible.
The heater must be applied and operated under the gen-
eral concepts of resonable use.
This appliance is not intended for use by persons (includ-
ing children)
w
ith reduced physical, sensory or mental
capabilities, or lack of experience and kno
w
ledge, unless
they ha
v
e been gi
v
en super
v
ision or instruction concern-
ing use of the appliance by a person responsible for their
safety.
Children should be super
v
ised to ensure that they do no
play
w
ith the appliance.
For additional copies of the Installation, Operation and
Ser
v
ice Manual, please contact Roberts-Gordon Europe
Limited.
1.1 Manpower Re
q
uirements
To pre
v
ent personal injury and damage to the heater, t
w
o
persons
w
ill be required for installation.
1.2 IP55 Protection
The burner is certified to protection class of IP55. This
means that the internal components of the burner are
protected against extreme dusty atmosphere and
w
ater
jets from all sides. Outside air supply and flue are
mandatory for this heater. The standard exhaust fans
mentioned in this manual do NOT ha
v
e IP55 protection
and must be outside the
w
et en
v
ironment. If the fan is to
be installed in the
w
et en
v
ironment, a special IP54
protected fan must be used. Consult Roberts-Gordon
LLC for alternati
v
e exhaust fans. Optional stainless steel
burner box pro
v
ides long life in the most corrosi
v
e
applications. Al
w
ays ensure that the en
v
ironment to be
heated is not of an explosi
v
e or flammable nature. For
more information, please consult your ROBERTS
GORDON
®
representati
v
e.
In order to ha
v
e trouble free performance of your
BLACKHEAT
®
AG heater and maintain the IP55
protection, follo
w
all instructions in this manual, especially
the replacement of sealing gaskets.
1.3 Safety Labels and Their Placement
Product safety signs or labels should be replaced by
the product user
w
hen they are no longer are
legible. Please contact Roberts-Gordon LLC or your
ROBERTS GORDON
®
independent distributor to
obtain replacement signs or labels.
See Page 3,
Figure 1
through Page 3, Figure 2
.
Summary of Contents for AG15ST
Page 2: ......
Page 4: ......
Page 6: ......
Page 45: ...SECTION 11 WIRING 39 11 4 Internal Wiring Diagram ...
Page 53: ...SECTION 14 TROUBLESHOOTING 47 Troubleshooting Flow Chart Linear and Double Linear ...
Page 61: ......