SECTION 5: GENERAL SUSPENSION DETAILS
To ensure your safety, and comply
w
ith the terms of the
w
arranty, all units must be installed in accordance
w
ith
these instructions.
The gas or the electrical supply lines must not be used to
support the heater.
Do not locate the gas or electric supply lines directly o
v
er
the path of the flue products from the heater.
The heater must be installed in a location that it is readily
accessible for ser
v
icing.
The heaters must be installed in accordance
w
ith
clearances to combustibles as indicated on the rating
plate and in this manual.
The minimum and maximum gas inlet pressures must be
maintained as indicated on the rating plate. Typical
installation configurations are sho
w
n in
Figure 9
.
NOTE: Some models may recei
v
e S-hooks (P/N
91907302) or spring hooks (P/N91903300), rather than
bo
w
shackles.
WARNING
Severe Injury Hazard
Secure burner to burner tube with bolts and
lockwashers.
Hang heater with materials with a minimum
working load of 75 lbs (33 kg).
Failure to follow these instructions can result
in death, injury or property damage.
WARNING
Cut/Pinch Hazard
Wear protective gear during installation,
operation and service.
Edges are sharp.
Failure to follow these instructions can result
in injury.