Section A - 9
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing
techniques without prior notice.
TECHNICAL FILE
1800W MSR FOLLOWSPOTS
FLO / VICTOR
PLACING THE LAMP.
User's precautions:
- Use only Philips MSR 1800DE lamp.
- Disconnect from the mains.
- Lamp is cold.
- Avoid touching the bulb of the lamp.
- Open the side trapdoors of the lamp house.
- Use only when lamp is in place.
Preparing the lamp:
- Unscrew the nuts 1 without completely taking them off.
Installing the lamp :
- Place the lamp into the contacts 2 and
the tip-off in the upper position D .
- Tighten the nuts 1 firmly, by hand.
Warning : A bad lamp tightening can cause
a bad contact and a defective
ignition. Check regularly that the
nuts 1 are well tightened.
Lamp :
Warning - Do not use a lamp, if the diameter
of the bulb is greater than Ø28,5mm.
- No matter in what the position of the circuit breaker 3 ,
make sure that the mains checklight 4 is ON.
- Engage the circuit breaker 3 .
- Press the switch 5 to "ON" .
- To switch the lamp off, press the switch to the "OFF" position.
Warning : • Carry out the connections before
connecting to the mains (refer to section A - 5 or 7).
• Let the lamp house fan run for 10 min before switching
the circuit breaker off.
Ø28,5mm Maxi
180
1
2
2
1
A
B
C
E
D
A
B
C
D E
Disconnect from the mains before any servicing.
Service only by qualified technician.
4
3
5
SWITCHING ON /OFF
Summary of Contents for Victor 1159
Page 2: ...ii NOTES...