Section A - 7
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat r
eserve the right to change or alter any of the items detailed on this page, to incr
ease or impr
ove manufacturing
techniques without prior notice.
TECHNICAL FILE
1800W MSR FOLLOWSPOTS
VICTOR
Power supply unit
(P.S.U.)
CONNECTIONS.
Mains voltage.
- Check the conformity of the power supply unit C .
Rating plate 10 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lighting unit's power cable B by passing it
inside the yoke.
- Leave a little slack and then block the cable B into the lock d .
- Place the lamp into position - refer to section A - 9.
- Connect the cable 2 to the mains.
CAUTION - For your security !
- Never open the lamp house's bonnet and trapdoors
when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when the lamp is in place.
DESCRIPTION.
A
1800W Hot restrike followspot.
B Lighting unit's power cable.
Cable 18G 1,5mm
2
, length 3m equipped
with 16 x 16A male HARTING connector.
C Power supply unit.
1 - EF HARTING 16 x 16A - 2 latch connector.
2 - Mains cable socket.
3 - Time meter.
4 - General 16A circuit breaker (E.C).
- General 15A circuit breaker (
UL/CSA).
5 - 5 x 20 Fuse holder (2A 250V).
6 - Mains, checklight.
7 - "ON/OFF" switch.
8 - Lamp ON, checklight.
If the lamp's checklight is OFF when the switch is
ON, the lighting of the lamp has failed.
Repeat the operation - refer to section A - 9.
9 & 10 - Rating plate.
Make sure the fan is working correctly
when switching on the unit.